Processors principles of operation for ecps: vse mode (314 pages)
Summary of Contents for IBM B32
Page 1
IBM Converged Switch B32 Installation, Service, and User Guide Service information: 3758-B32, 375832E, 3758-L32 Read Before Using This product contains software that is licensed under written license agreements. Your use of such software is subject to the license agreements under which they are provided.
Page 3
IBM Converged Switch B32 Installation, Service, and User Guide Service information: 3758-B32, 375832E, 3758-L32 GC52-1358-01...
Read this first Summary of changes This is the second edition of the IBM Converged Switch 32B Installation, Service, and User Guide. The content changes since the last edition of this publication are noted by a vertical line placed in the left margin beside each change. Minor edits are not identified by this mark.
GUI. Vendor software This product includes certain vendor software that is not covered under the IBM license agreement. IBM makes no representation about the accessibility features of these products. Contact the vendor for the accessibility information about its products.
Your feedback is important in helping us provide the most accurate and high-quality information. If you have comments or suggestions for improving this document, send us your comments by e-mail to starpubs@us.ibm.com. Be sure to include the following: v Exact publication title...
Page 8
Converged Switch B32 Installation, Service, and User Guide...
. iii Time required . 15 Taiwan Contact Information . . iv Items required . . 16 Accessibility features for the Converged Switch B32 Installation instructions . . 17 Accessibility features . . iv Configuring the switch . 21 Keyboard navigation .
Page 10
Notices ....57 Trademarks . . 59 Index ....63 Electronic emission notices . . 60 viii Converged Switch B32 Installation, Service, and User Guide...
Tables Sample caution notices. . xv Management options for the switch . 38 Brocade and IBM product and model number Switch dimensions . . 51 matrix . . xxii Power supply specifications . . 52 Parts supplied with the rack-mount kit Environmental requirements .
Page 14
Converged Switch B32 Installation, Service, and User Guide...
IBM Systems Safety Notices (G229–9054) publication, which is on the CD-ROM that accompanies this product. The following notices and statements are used in IBM documents. They are listed below in order of increasing severity of potential hazards. Follow the links for more detailed descriptions and examples of the danger, caution, and attention notices in the sections that follow.
Page 16
(D004) A general electrical danger notice provides instructions on how to avoid shock hazards when servicing equipment. Unless instructed otherwise, follow the procedures in the following danger notice. Converged Switch B32 Installation, Service, and User Guide...
Electrical voltage and current from power, telephone, and communication cables are hazardous. To avoid a shock hazard: v Connect power to this unit only with the IBM provided power cord. Do not use the IBM provided power cord for any other product.
As an added precaution, safety labels are often installed directly on products or product components to warn of potential hazards. These can be either danger or caution notices, depending upon the level of the hazard. Converged Switch B32 Installation, Service, and User Guide...
The actual product safety labels may differ from these sample safety labels: DANGER Hazardous voltage, current, or energy levels are present inside any component that has this label attached. Do not open any cover or barrier that contains this label. (L001) DANGER Rack-mounted devices are not to be used as a shelf or work space.
Attempting to move the drawer partially or completely out of the rack might cause the rack to become unstable or cause the drawer to fall out of the rack. (R001 part 2 of 2) xviii Converged Switch B32 Installation, Service, and User Guide...
Rack relocation (19″ rack) CAUTION: Removing components from the upper positions in the rack cabinet improves rack stability during relocation. Follow these general guidelines whenever you relocate a populated rack cabinet within a room or building: v Reduce the weight of the rack cabinet by removing equipment starting at the top of the rack cabinet.
Product recycling and disposal Refer to the IBM Systems Environmental Notices and User Guide (Z125-5823) on the environmental notices CD for translated environmental statements and information regarding product recycling and disposal. For instructions on removing the battery from this product, see “Removing the battery”...
(SAN) technologies. It describes how to install, service, and use the IBM Converged Switch B32 (machine type 3758, model B32, and model L32). Throughout this document, the product is referred to as the B32, or simply the switch. The base unit of model 3758-L32 is licensed only for Converged Enhanced Ethernet (CEE), while the 3758-B32 model is licensed for both CEE and Fibre Channel over Ethernet (FCoE).
When you use any of the Brocade documents, you will notice that the model numbers reflect the original Brocade products. Table 2 provides a product matrix for you to use to correlate the Brocade products and models to the IBM product names and machine types and model numbers. Products withdrawn from marketing are not listed.
3758-B32, which is licensed for Fibre Channel over Ethernet (FCoE), Fibre Channel (FC), Converged Enhanced Ethernet (CEE), and traditional Ethernet protocols; and the 3758-L32, which is a CEE-only switch in the base unit configuration. The IBM Converged Switch B32 features a top-of-rack, 1U, 32-port multiprotocol design that supports Fibre Channel over Ethernet (FCoE), Fibre Channel, Converged Enhanced Ethernet (CEE), and traditional Ethernet protocols.
FCoE and Layer 2 capabilities The switch has the following capabilities for the Ethernet functions: Note: FCoE is available on the 3758-B32 and the 3758-L32 with FC7408, FC and Converged Activation. v 24 ports 10 GbE CEE v Provides a low latency, lossless, deterministic interconnect required for FCoE...
System status LED (top) GbE ports 8-15 System power LED (bottom) Serial console port GbE ports 16-23 Management Ethernet port Fibre Channel ports 0-7 (active on the 3758-B32, and the 3758-L32 upgraded with FC and Converged Activation) USB port Chapter 1. Product overview...
SAN b-type fabric switches, while preserving in-order delivery. You can use ISL Trunking between any of the supported 2–, 4–, or 8–Gbps b-type models. Both SAN b-type switches must have ISL Trunking activated. Converged Switch B32 Installation, Service, and User Guide...
Page 29
For information on these features, see the Fabric OS Administrator’s Guide. Chapter 1. Product overview...
Page 30
Converged Switch B32 Installation, Service, and User Guide...
– One slide-rail rack mount kit, with instructions – SFP transceivers (quantity and type depending upon features ordered) – Converged Switch B32 Installation, Service, and User Guide (this document). – Product documentation CD – Environmental notices CD – Paperpack of optional features activation information (if ordered) Attention: Retain this paperpack in a safe place.
The equipment in the cabinet is grounded through a reliable branch circuit connection and maintain ground at all times. Do not rely on a secondary connection to a branch circuit, such as a power strip. Converged Switch B32 Installation, Service, and User Guide...
v Airflow must always be from front to back with respect to the rack. The device must not interfere with the cooling of other systems in the rack. Fillers must be used as appropriate in the rack to ensure there is no recirculation of heated exhaust air back to the front of the rack.
Be sure to use the referenced parts when you perform each step. Before you start the rack-mount installation process, locate the rack-mount slides and the mounting bracket that are provided in the shipping container. Converged Switch B32 Installation, Service, and User Guide...
Figure 3 shows the rack assembly. The number keys, such as 1 , refer to the items listed in Table 3. Outer Slide EIA Rack Rail Inner Slide Detail A Front of Switch Detail A SJ000153 Figure 3. Rack assembly 1.
(away from the ports) as shown in Figure 5 on page 13. b. Attach the inner rail by using three of the 8-32 x 3/16 in. zinc screws ( 6 in Table 3 on page 11). Converged Switch B32 Installation, Service, and User Guide...
Front SJ000047 Figure 5. Mounting the moving portion of the slide and mounting brackets to the switch c. Repeat step 3a on page 12 and step 3b on page 12 for the second inner rail on the other side of the switch chassis. 4.
Position the switch in front of the rack. Insert the switch into the rack by sliding the inner slides that are mounted on the switch into the outer slides that are mounted on the rack. See Figure 7 on page 15. Converged Switch B32 Installation, Service, and User Guide...
SJ000049 Figure 7. Inserting slides into the rack rails b. Check the alignment of the slides by sliding the switch in and out of the rack. Any difficulty moving the switch indicates lateral stress or misalignment. If this situation occurs, adjust the slide positions until the movement is smooth.
scale: 3/16" = 1" (12x) (8x) (8x) (8x) (8-32 x 5/16 in.) (6-32 x 1/4 in.) (10-32 x 5/8 in.) (10-32) Figure 8. Mid-mount rack kit parts Installation instructions Attention: The switch must be turned off and disconnected from power and from the fabric during this procedure.
Attaching the front brackets to the rack 1. Position the switch in the rack (Figure 10 on page 19), providing temporary support under the switch until the rail kit is secured to the rack’s rails. Converged Switch B32 Installation, Service, and User Guide...
Figure 10. Attaching the front bracket to the rack 2. Attach the right front bracket ( 1 ) to the right front rack rail using three 10-32 x 5/8 in. screws ( 5 ) and three retainer nuts ( 6 ). 3.
1. Align the right rear bracket to the right rear of the switch, and using two 10-32 x 5/8 in. screws ( 5 ) attach the bracket to the switch (Figure 12 on page 21). Converged Switch B32 Installation, Service, and User Guide...
EZSwitchSetup to complete the basic configuration. See the EZSwitchSetup CD, included with the switch, for more information. You can also use the IBM Converged Switch B32 Quick Start Guide for more guidance. If you do not use EZSwitch Setup, follow the instructions in the resmainder of this section.
4. After POST is complete, verify that the System Status and Power Status LEDs (see 6 in Figure 1 on page 3) display steady green. For more information about the LEDs and their status during POST, refer to “Interpreting LED activity” on page 30. Converged Switch B32 Installation, Service, and User Guide...
Creating a serial connection You will perform all basic configuration tasks in this guide using a serial connection. To create a serial connection to the switch, complete the following steps: 1. Remove the plug from the serial console port (if any) and insert the serial cable provided with the switch.
By default, all switches are in the GMT time zone (0,0). If all switches in a fabric are in one time zone, it is possible for you to keep the time zone setup at the default setting. Converged Switch B32 Installation, Service, and User Guide...
v System services that have already started will reflect the time zone changes only after the next reboot. v Time zone settings persist across failover for high availability. Local time synchronization You can synchronize the local time of the principal or primary fabric configuration server (FCS) switch to a maximum of eight external network time protocol (NTP) servers.
IP address or DNS name of the first NTP server, which the switch must be able to access. The second ntp2 is the second NTP server and is Converged Switch B32 Installation, Service, and User Guide...
optional. The entire operand “<ntp1;ntp2>” is optional; by default, this value is LOCL, which uses the local clock of the principal or primary switch as the clock server. switch:admin> tsclockserver LOCL switch:admin> tsclockserver "132.163.135.131" switch:admin> tsclockserver 132.163.135.131 switch:admin> The following example shows how to set up more than one NTP server using a DNS name: switch:admin>...
Page 52
Converged Switch B32 Installation, Service, and User Guide...
The left LED ( 5 ) corresponds to the upper port, and the right LED ( 6 ) corresponds to lower port in each pair. Refer to Figure 1 on page 3 for the locations of the GbE and FC ports. Converged Switch B32 Installation, Service, and User Guide...
Figure 13. LEDs on the port side of the switch System power LED Ethernet link LED System status LED GbE port status LED (port 0) Ethernet speed LED GbE port status LED (port 4) Chapter 3. Operating the switch and monitoring components...
Reboot the system. amber during POST, this is normal v Check the failure indicated on the system console. and does not indicate a fault. If the problem does not resolve, contact your IBM representative. Flashing amber Attention is required. A number of...
Ethernet management port LED patterns The Ethernet management port has two LEDs to indicate Ethernet speed ( 3 Figure 13 on page 31) and Ethernet link ( 4 ). Table 7 describes the meaning of different displays of the Ethernet LEDs and recommended action, if any. Table 7.
LEDs nonport side of the switch. Figure 14. Nonport side LEDs Power supply #2 status LED Fan assembly #2 status LED Power supply #1 status LED Fan assembly #1 status LED Fan assembly #3 status LED Converged Switch B32 Installation, Service, and User Guide...
Power supply status LED patterns The power supply status LEDs ( 1 and 2 in Figure 14 on page 34) indicate the status of the individual power supplies. Table 9 describes the meaning of different displays of the power supply LEDs and recommended action, if any. Table 9.
POST. Contact your IBM representative 3. Review the switch system log for errors. Any errors detected during POST are written to the system log, accessible through the errShow command. Converged Switch B32 Installation, Service, and User Guide...
For information about all referenced commands, and on accessing the error log, refer to the Fabric OS Administrator’s Guide. For information about error messages, refer to the Fabric OS Message Reference. Diagnostics and troubleshooting The switch is designed for high availability and low failure. It does not require any regular physical maintenance.
Select the correct product link v On the specific product page, click the Interoperability Matrix link. Firmware release notes and download files are available through the IBM SAN Support web pages. To view release notes and to download firmware: v Go to www.ibm.com/systems/support.
Page 63
v On the next page that is displayed, select Download, and then select Storage area network (SAN). v Select your product, then select the appropriate firmware version release notes. Review the release notes before installing the firmware update. v Select the firmware download version and follow the online prompts. Chapter 3.
Page 64
Converged Switch B32 Installation, Service, and User Guide...
2. Power off the defective power supply by pressing the AC power switch to "O". See 7 in Figure 16 on page 43. 3. Unplug the power cord from the power supply that you are replacing. Converged Switch B32 Installation, Service, and User Guide...
4. Using a Phillips screwdriver, unscrew the captive screw ( 5 in Figure 16). Figure 16. Removing and replacing a power supply 1 switch chassis 5 captive screw 2 power supply 6 AC power receptacle 3 status LED 7 AC power switch 4 handle 5.
Fan 1 is Ok, speed is 4821 RPM Fan 2 is Ok, speed is 4891 RPM Fan 3 is Ok, speed is 4821 RPM sw8000:admin> Time required Less than 2 minutes. Converged Switch B32 Installation, Service, and User Guide...
Items required v New fan assembly v Phillips screwdriver #1 Procedure Attention: Disassembling any part of the fan assembly voids the part warranty and regulatory certifications. There are no user-serviceable parts inside the fan assembly. Since the cooling system relies on pressurized air, do not leave any of the fan assembly slots empty longer than 2 minutes while the switch is operating.
For the GbE ports, use the cmsh command. For a listing of SFPs compatible with this product: v Go to the IBM SAN Support web page at www.ibm.com/servers/storage/ support/san v Select the product family, Storage Area Network (SAN), from the Product family list.
Follow these steps and the links to more detailed instructions to replace the switch. Removing the switch 1. Verify that the replacement switch is the correct part number (45W2442 for the 3758-B32, 45W2443 for the 375832E, or 45W6765 for the 3758-L32). Chapter 4. Removing and replacing CRUs...
Page 72
(Refer to “Installing the switch in a cabinet” on page 10 for illustrations and complete rack mount instructions.) 10. Set the switch aside for later return to IBM, following the instructions included with the replacement switch. Installing the CRU switch Follow these steps to install the replacement for the switch you removed earlier.
Removing the battery Local regulations may require the removal and recycling of the battery prior to disposal of the product. To remove the battery from the Converged Switch B32, complete these steps: 1. Unscrew fasteners to remove any installed modules.
Figure 20. Battery location on circuit board 5. Remove the BR1225 battery. 6. Recycle the battery as required. Refer to the Environmental Notices and User Guide shipped with the product for more information on battery recycling and disposal. Converged Switch B32 Installation, Service, and User Guide...
General specifications Table 15 lists the general specifications for the switch. Table 15. General specifications Specification Description Configurable port types F_Port, FL_Port, E_Port, and M_Port System architecture Nonblocking shared-memory switch System processor Freescale MPC8548 x 1.3GHz ANSI Fibre Channel protocol FC-PH (Fibre Channel Physical and Signalling Interface standard) Modes of operation...
IP network. The serial port’s parameters are fixed at 9600 baud, 8 data bits, and no parity, with flow control set to None. Converged Switch B32 Installation, Service, and User Guide...
Refer to Figure 1 on page 3 and Figure 2 on page 4 for the location of the parts listed below. Part numbers are subject to change, particularly for SFP transceivers. Contact your IBM representative for current information on part numbers for SFPs to meet your needs.
Page 80
Converged Switch B32 Installation, Service, and User Guide...
The materials at those web sites are not part of the materials for this IBM product and use of those web sites is at your own risk.
Page 82
Information concerning non-IBM products was obtained from the suppliers of those products, their published announcements or other publicly available sources. IBM has not tested those products and cannot confirm the accuracy of performance, compatibility or any other claims related to non-IBM products.
International Business Machines Corporation in the United States, other countries, or both. A complete and current list of other IBM trademarks is available on the Web at http://www.ibm.com/legal/copytrade.shtml Brocade and SilkWorm are trademarks of Brocade Communications Systems, Inc., or its subsidiaries in the United States, other countries, or both.
Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. IBM is not responsible for any radio or television interference caused by using other than recommended cables and connectors or by unauthorized changes or modifications to this equipment.
Klasse A ein. Um dieses sicherzustellen, sind die Geräte wie in den Handbüchern beschrieben zu installieren und zu betreiben. Des Weiteren dürfen auch nur von der IBM empfohlene Kabel angeschlossen werden. IBM übernimmt keine Verantwortung für die Einhaltung der Schutzanforderungen, wenn das Produkt ohne Zustimmung der IBM verändert bzw.
People’s Republic of China Class A Electronic Emission Statement Japan VCCI Class A ITE Electronic Emission Statement Korea Class A Electronic Emission Statement Converged Switch B32 Installation, Service, and User Guide...
Page 88
51 power supply specifications 52 data transmission ranges 53 power supply status dimensions 51 LED patterns 35 environmental 52 LEDs 35 FC port 54 power-on self-test (POST) 36 general 53 latency 54 Converged Switch B32 Installation, Service, and User Guide...
Page 90
Part Number: 45W7215 Printed in USA GC52-1358-01...
Need help?
Do you have a question about the B32 and is the answer not in the manual?