|raid10pool:rd10vol3|
|raid10pool:rd10vol5|
|raid10pool:rd10vol4|
|raid10pool:rd10vol2|
|raid10pool:rd10vol6|
|raid10pool:rd10vol8|
|raid10pool:rd10vol7|
|___________________|____________|_________|
detail pool
The detail pool command provides detailed information about any pool. The pool
can be specified by a name or number. The -name option uses the pool name as
input.
Command arguments:
<CLI> detail pool [–name poolname | -number number]
Where:
v poolname - Defines the name of the pool.
v number - Refers to the sequence number on the list displayed when you issue the
Example:
<CLI> detail pool -name pool1
_____________________________________________________________________________________________
| ID | Name
|____|___________|________|_________|________|________|_____________|__________|____________|
|
|____|___________|________|_________|________|________|_____________|__________|____________|
When the pool is specified by a number, that number refers to the sequence
number that appears on the list displayed when issuing the list pool command.
Issue the list pool command before you issue detail pool with the –number
option, so that there is an internal reference list. If you do not issue the list pool
command first, an error displays.
Any volume service currently running on this pool also displays in the status.
The state definitions are:
v UN - Unmounted, Non-viable
v MF - Mounted, Failed
v UF - Unmounted, Failed
v DN - Dismounted, Non-viable
v DF - Dismounted, Failed
v UV - Unmounted, Viable
v DV - Dismounted, Viable
v MV - Mounted, Viable
v MN - Mounted, Non-viable
52
IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module
list pool command.
|RaidType|OwnerCtlr|TotalCap|AvailCap| Status
2|
DG2|
1|
Note: One or more drives are missing in this pool. You must acknowledge an
alert pertaining to this state. If the missing drive comes back to make the pool
viable, the state automatically changes to MV. When you acknowledge the alert,
the state of the pool becomes UN.
10|
174GB|
10|
174GB|
10|
174GB|
10|
174GB|
10|
174GB|
10|
174GB|
10|
174GB|
IO 3|
33GB|
28GB|
| State
| Degraded
Viable|
MV|
|
No|
Need help?
Do you have a question about the BladeCenter S SAS RAID Controller Module and is the answer not in the manual?
Questions and answers