IBM BladeCenter S SAS RAID Controller Module Installation And User Manual page 32

Sas raid controller module
Table of Contents

Advertisement

10. If you have two SAS RAID Modules, repeat these steps to enable Fast POST
What to do next
If you experience any problems with setting these parameters, review the
advanced verification procedures in the Troubleshooting section of this document.
22
IBM SAS RAID Controller Module: Installation and User's Guide IBM BladeCenter S SAS RAID Controller Module
If you have the Advanced Management Module connected to your
network, log in using the network IP assigned to it. If you are using the
default IP address your management system (the computer you are using
to manage your IBM BladeCenter S components) must be physically
connected through an Ethernet cable to the Advanced Management
Module .
Note: The default IP address for the Advanced Management Module is
192.168.70.125.
b. Enter the username and password.
v The default username is: USERID
v The default password is: PASSW0RD (the sixth position is the numeral
zero)
c.
When prompted for the Inactive session timeout value, select no timeout.
Note: Remember to log out when you have completed your session. If you
do not log out, the system shows an error the next time you try to log in.
2. Click Continue.
3. From the I/O Module Tasks menu, click Configuration.
4. From the I/O Module Configuration section, click Bay 3
5. Enter the IP settings for the SAS Switch, and RAID Controller.
6. Save the settings.
7. If you have two SAS RAID Modules, repeat these steps to configure the IP
settings for the SAS Switch, and RAID Controller in Bay 4 as well.
8. Verify the IP settings are listed before proceeding to the next step.
9. Enable Fast POST and ensure that External ports are disabled for each RAID
Controller.
Note: The disabled ports are SAS ports, not Ethernet ports.
a. From the I/O Module Tasks menu, click Admin/Power/Restart.
b. Scroll down to the I/O Module Advanced Setup section and from the
Select a module menu, select I/O module 3.
c. Select Enabled from the menu for Fast POST and Disabled for External
ports.
d. Click Save.
and ensure that the External ports are disabled for the RAID Controller
installed in I/O module 4 as well.

Advertisement