IBM BladeCenter S SAS RAID Controller Module Installation And User Manual page 123

Sas raid controller module
Table of Contents

Advertisement

5013
Drive enclosure enclosure_ID warning - power supply current out of range
Explanation: Drive enclosure power supply current is not yet critical, but is out of the normal operating range.
Potential causes are power supply failure and current sensor failure.
System action: By default, the SAS RAID Module system information indicator is turned on and the operator is
notified of this alert by e-mail. The alert clears automatically when the current returns to the normal operating range.
Operator response:
1. Replace the drive enclosure power supply.
2. If the problem persists, the current sensor in the enclosure might be failing. Replace the drive enclosure (see
"Replacing a Disk Storage Module (non-concurrent procedure)" on page 161).
This alert can be masked so that it does not trigger the SAS RAID Module system information indicator.
5014
Drive enclosure enclosure_ID firmware mismatch exists. Reboot system or execute controller firmware
update.
Explanation: The controller queries the firmware revision level of each drive enclosure in the system. During system
boot up or as part of controller firmware upgrade, the controller automatically updates all connected drive
enclosures. However, connecting a drive enclosure to a system that is already operational does not trigger a firmware
update. If the drive enclosure firmware revision does not match the current controller firmware level, alert 5014 is
generated.
System action: By default, the SAS RAID Module system information indicator is turned on and the operator is not
notified of this alert by e-mail. Alert clears when the firmware in the drive enclosure is updated.
Operator response: You can correct the firmware mismatch by performing either of the following tasks:
v If the firmware revision of the drive enclosure is compatible with the procedure, perform a concurrent controller
firmware update..
v Reboot the system. The controller automatically updates the drive enclosure firmware as part of the boot-up
procedure.
Note: The drive enclosure firmware update process can take minutes to complete. During that time, the system will
be offline and unavailable.
This alert can be masked so that it does not trigger the SAS RAID Module system information indicator.
9004
Drive enclosure enclosure_ID firmware update failed
Explanation: A drive enclosure firmware update has failed. The firmware update happens either automatically at
system boot-up (because the firmware revision level of the drive enclosure does not match the current controller
firmware level) or as part of a controller firmware update procedure.
System action: By default, the SAS RAID Module system information indicator is turned on and the operator is not
notified of this alert by e-mail. Alert clears when the enclosure is removed or another firmware update is initiated.
Operator response:
1. Acknowledge to clear the alert immediately.
2. Try again to update the drive enclosure firmware.
3. If this update is unsuccessful, perform a non-concurrent controller firmware update.
4. If the problem persists, perform a Disk Connectivity Diagnosis.
5. If no other solution has worked, replace the drive enclosure (see "Replacing a Disk Storage Module
(non-concurrent procedure)" on page 161).
Chapter 11. Troubleshooting and support
5013 • 9004
113

Advertisement

Table of Contents
loading

Table of Contents