27.
Measured values: What is the temperature? How many packet errors are there? The
monitor function returns actual measured values for the port and temperature
indicators.
Temperature monitoring measures the temperature using the Fahrenheit or Celsius scale.
Port monitoring measures error packets as CRC, Runts and Overrun.
(Total
packets
Alert Behavior
An alert is generated when the Power indicator reports a Failed condition
the Temperature or Port indicator diverges from a preset limit value.
Two kinds of alert action are available:
log – the alert status is written to a CLI interface's history and error message log files
trap – an SNMP trap is generated.
Any or all of these actions can be assigned to an alert status. Alert behavior can be configured
globally for all monitored indicators, or individually for specific indicators.
How Alerts are Triggered
There are two types of monitored indicators:
Pass/Fail conditions: Is the power supply working? The monitor function returns a
simple Pass or Fail status for power. When alert notification is enabled, alerts are
triggered when the status is Fail.
Measured values: What is the temperature? How many packet errors are there? The
monitor function returns actual measured values for temperature and port operation.
The limit and delta commands in Monitoring Configuration mode are used to define
alert notification triggers for these indicators.
Limit-based Alert Triggering
A reference value can be set for the temperature,CPU and RAM indicator by using the limit
command in Monitoring Configuration mode. You can set the condition that alerts will be
generated only on the instance that the measured value rises above this reference, or only
when it drops below this reference, or when it crosses the reference in either direction. For
example, if you set alerts to be triggered when the measured value crosses the limit of 5 in
either direction:
An alert is triggered when the last measurement was 4 and the latest measurement is
6.
No new alerts are triggered as long as measurements remain above 5.
An alert is triggered when the measured value falls back below 5.
When the limit command is used alone, alerts are triggered only when the measured value
crosses the limit value. The delta command in Monitoring Configuration mode can be used to
configure a range of alert triggers relative to the limit value.