Nokia ESB26 User Manual page 19

Gigabit ethernet switch
Table of Contents

Advertisement

2.
Step 1. Insert the device into its chassis slot.
Step 2. Attach an RS-232 ASCII terminal to the RJ-45 (SER1) connector (See Figure 2-1).
Step 3. Configure the terminal to operate at:
25 lines and 80 columns window size
Step 4. Establish a session with the unit and power on the unit. After a few seconds, the
following is displayed on the terminal screen:
Press any key to stop auto-boot...
0
Verifying validity of primary application.....OK
Start primary application...
BUILT-IN SELF TEST
------------------
CPU Core Test
CPU Notify RAM Test
CPU Interface Test
Testing Switch Core
On-board Power Test
////////////////////////////////////////////////////////////////////////
//
//
N O K I A
//
//
//
Switch model : NOKIA ESB26
//
SW version
: 3.2.89 ER created Dec 17 2003 - 11:32:40
//
////////////////////////////////////////////////////////////////////////
User Access Verification
Password:
Step 5. Enter your password, which is nokia by default. The device-name
displayed, allowing you to begin the configuration process.
MN700004 Rev 01
Getting Started
Emulation mode: VT-100 mode (default mode)
9600 bps
8 data bits
1 stop bit
No parity
No flow control
: Passed
: Passed
: Passed
: Passed
: Passed
8
//
//
//
//
//
//
//
prompt is
>

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents