Brocade Communications Systems Brocade 8/12c Command Reference Manual page 785

Brocade fabric os command reference manual supporting fabric os v7.0.0 (april 2011)
Hide thumbs Also See for Brocade 8/12c:
Table of Contents

Advertisement

NOTES
Do not abort this test prematurely, using CTRL-C or q to quit. Doing so may cause the test to report
unexpected errors.
This command does not support High Availability (HA).
The Brocade DCX series cannot negotiate speeds of 1 Gbps.
The switch must be disabled before you can run this diagnostics.
The Brocade FCoE10-24 blade (ceePortLoopbackTest) supports only lb_mode 1, 2, and 8.
The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in
place. Refer to Chapter 1, "Using Fabric OS Commands" and Appendix A, "Command Availability" for
details.
OPERANDS
This command has the following operands:
--slot slot
-nframes count
-lb_mode mode
-spd_mode mode
Fabric OS Command Reference
53-1001764-01
CSPAT: 0x7e, 0x7e, 0x7e, 0x7e, ...
BYTE_LFSR: 0x69, 0x01, 0x02, 0x05, ...
CHALF_SQ: 0x4a, 0x4a, 0x4a, 0x4a, ...
QUAD_NOT: 0x00, 0xff, 0x00, 0xff, ...
CQTR_SQ: 0x78, 0x78, 0x78, 0x78, ...
CRPAT: 0xbc, 0xbc, 0x23, 0x47, ...
RANDOM: 0x25, 0x7f, 0x6e, 0x9a, ....
Specifies the number of the slot on which to run the diagnostics. All eligible ports
relative to the slot number are tested. The default is 0 and designed to operate on
fixed-port-count products.
Specifies the number of frames to send. The test progresses until the specified
number of frames has been transmitted on each port. The default value is 10.
Specifies the loopback mode for the test. By default, this test uses the internal
loopback. Valid values depend on the platform on which the command is
executed. Unsupported values are rejected with an appropriate message.
1
Port Loopback (loopback plugs)
2
External (SERDES) loopback
5
Internal (parallel) loopback
7
Backend bypass & port loopback
8
Backend bypass & SERDES loopback (supported only on a chassis)
Specifies the speed mode for the test. This parameter controls the speed at which
each port is operated.
0
Runs test at 2 Gbps, and 4 Gbps.
1
Runs test at 1 Gbps (deprecated).
2
Runs test at 2 Gbps.
22
portLoopbackTest
751

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fabric os v7.0.0

Table of Contents