Brocade Communications Systems Brocade 8/12c Command Reference Manual page 776

Brocade fabric os command reference manual supporting fabric os v7.0.0 (april 2011)
Hide thumbs Also See for Brocade 8/12c:
Table of Contents

Advertisement

22
portLogShow
ctin
errlog
loopscn
Args
Tx & Rx
reject
busy
742
Tx & Rx
Frame payload size.
scn
New state (see state codes below).
pstate
New physical state (see pstate codes below).
The CT-subtype:
fc
Simple Name Server.
f8
Alias Server.
ctout
The same as ctin.
Error level (refer to errShow).
The current loop state during loop initialization. Possible values areas follows:
OLP
Offline (disconnected or nonparticipating).
LIP
FL_Port entered INITIALIZING or OPEN_INIT state.
LIM
LISM completed, FL_Port became the loop master.
BMP
Loop init completed, FL_Port in MONITORING state.
OLD
Port transitioned to the OLD_PORT state.
TMO
Loop init times out.
Displays additional information about the event as follows:
start
Start type: 0 = enable ports, 100 = disable ports.
disable
State (refer to state codes).
enable
Mode: 0 normal; nonzero loopback.
Header words 0,1,4 (R_CTL,D_ID,S_ID,OX_ID,RX_ID) and the first payload
word.
FC-PH reject reason.
FC-PH busy reason.
Fabric OS Command Reference
53-1001764-01