Download Print this page

Extreme Networks EPICenter Reference Manual page 472

Hide thumbs Also See for EPICenter:

Advertisement

EAPS Protocol Monitoring and Verification
The top portion of the window shows information about the device in relation to each of the EAPS
domains of which it is a member. The lower area shows information about a selected domain node.
Select a node to display the Domain Node Detail and Protected VLAN information.
This tab shows the following information:
Table 51: Device Details window, Domain Nodes tab
Domain Nodes
Domain Node
Status
Mode
Primary
Secondary
Domain
Domain Node Detail
Enabled
Control VLAN Name
Control VLAN Tag
Hello Timer
Failed Timer
Failed Timer Action
Primary Port Status
Secondary Port Status
Protected VLAN
VLAN Name
VLAN Tag
The Shared Ports Tab
Figure 243
shows the Shared Ports tab of the Device Details window.
472
The name of the node given to the device as a member of a domain.
Status of the node: Can be Idle, Complete, Failed, Links Up, Links Down,
Preforwarding, Init, Precomplete, PreInit, or Unknown.
Whether the node acts as a Master or Transit node for this domain.
Primary port number
Secondary port number
The name of the domain to which this node belongs.
Whether this node is enabled as an EAPS node. True or false.
Name of the control VLAN
VLAN tag (ID) of the control VLAN
The interval at which the EAPS master polls to check the status of its EAPS
member nodes
The interval after a failure is detected before the Failed Timer expires
Action to be taken when Failed Timer expires
Status of the primary port: Up, Down, Blocked, or Unknown
Status of the secondary port: Up, Down, Blocked, or Unknown
The name of the protected VLAN
The ID of the protected VLAN
EPICenter Reference Guide