Table 4-5: Normal Mode Actions (To Be Continued - Tandberg Data SLR7-140 PROGRAMMER Manual

Scsi interface functional specification
Table of Contents

Advertisement

Current Mode
Next Command
WRITE
move-group
read-group
navigate-group
write-group
Tandberg Data
Actions
Data and tapemarks remaining in the data buffer are written to the
tape. If this operation is successful the Drive enters the MOVE
mode. The move- group command is executed.
The Drive terminates the read-group command immediately with
CHECK CONDITION status. The Error Code is set to either E
DATA DETECTED
whether the tape is positioned before or after LEW. The Drive
continues to be in WRITE mode.
If the navigate-group command is a SPACE forward command, the
Drive terminates the command immediately with CHECK
CONDITION status. The Error Code is set to either E
DETECTED
whether the tape is positioned before or after LEW. The Drive
continues to be in WRITE mode. In other cases the Drive enters
NAVIGATE mode and the navigate-group command is executed.
A test is made to see if the current Density Code (tape format) has
changed. The write-group command is executed if the tape format
has not changed.
Table 4-5: Normal Mode Actions
4-8
Tandberg SLR Product Line SCSI Functional Specifications
or E
-
-
ND
OF
DATA DETECTED AFTER
or E
-
-
ND
OF
DATA DETECTED AFTER
Commands
-
ND
OF
LEW depending on
-
-
ND
OF
DATA
LEW depending on
-

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SLR7-140 PROGRAMMER and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Slr7Slr50Slr60Slr75Slr100Slr140

Table of Contents