28.
BYTE
BIT 7
Operation Code 00h
00
01
Logical Unit Number (LUN)
02
RESERVED
03
RESERVED
04
RESERVED
05
Control Byte
Table 28-1:
Sense Key
AS/AQ
ILLEGAL REQUEST
25h/00h
NOT READY
04h/01h
NOT READY
04h/02h
NOT READY
30h/03h
NOT READY
3Ah/00h
Test Unit Ready
28.1. Command Description
The TEST UNIT READY command provides a means to check if
the Drive is ready for a medium access command. If the
Drive would accept an appropriate medium access command
without returning CHECK CONDITION status, this command
will return GOOD status. See the section on Command Set
Summary for the list of Medium Access Commands.
The
Drive
will
command.
28.2. Command Descriptor Block
6
5
TEST UNIT READY Command Descriptor Block
28.3. Exception Handling
See section Error Conditions For All Commands.
In addition the TEST UNIT READY command will respond
with CHECK CONDITION status in the following situations:
Description
LOGICAL UNIT NOT
SUPPORTED
LOGICAL UNIT IS IN THE
PROCESS OF BECOMING
READY
LOGICAL UNIT NOT READY,
INITIALIZING COMMAND
REQUIRED
CLEANING CARTRIDGE
INSTALLED
MEDIUM NOT PRESENT
Table 28-2: TEST UNIT READY Response
28-1
Tandberg SLR Product Line SCSI Functional Specifications
not
disconnect
4
3
RESERVED
Comments
The LUN field of the IDENTIFY message or
in the CDB is not zero.
The Drive is performing an auto-load or a
load operation. This response is produced
only when the BSYA bit of the Miscellaneous
Parameters Page is set to 1.
The medium is inserted, but not loaded. The
Initiator should issue a LOAD command.
The Drive can not perform media accesses
on a cleaning cartridge.
There is no medium or the medium has been
ejected.
when
executing
2
1
this
0