12.3.4.

Modifiable Parameter Values

Only the following parameters can be modified by LOG
SELECT command:
Buffer Overrun Counter
Buffer Underrun Counter
Rewrite Counter
Total Write Error Counter
Total Write Error Corrected Counter
Total Bytes Written Counter
Total Uncorrected Write Error Counter
Reread Counter
Total Read Error Counter
Total Read Error Corrected Counter
ECC Correction Counter
Total Bytes Read Counter
Total Uncorrected Read Error Counter
ECC Error Counter
TapeAlert Flags
Logical Data Block Counter
Write Media Block Counter
Read Media Block Counter
Filemark Counter
Setmark Counter
Servo Lock Retry Counter
Servo Track Seek Counter
Write Servo Lock Lost Counter
Write Servo Dropout Counter
Read Servo Lock Lost Counter
Read Servo Dropout Counter
Any attempt to modify other Log Parameter Values and
their DU bits will be ignored.
12.3.5.

The TapeAlert Information Page

The supported TapeAlert flags may be set to one in a Log
Select with PCR set to zero and PC set to 01b. Any
attempts to set other flags will be ignored.
NOTE: The possibility to set the supported TapeAlert flags
with a Log Select is included for test purpose only.
12-6
Tandberg SLR Product Line SCSI Functional Specifications
Log Select