19.
BYTE
BIT 7
00
Operation Code 3Ch
01
Logical Unit Number (LUN)
02
Buffer ID
03
Buffer Offset
04
05
06
Allocation Length
07
08
09
Control Byte
Table 19-1:
Read Buffer
19.1. Command Description
The READ BUFFER command is mainly used in conjunction
with the WRITE BUFFER command as a diagnostic function
for testing the Drive's data buffer and the SCSI-bus
integrity.
The READ BUFFER command may also be used for debugging
by transferring debugging data to the initiator.
This command will not alter the status of a possibly
inserted tape cartridge in any way.
The READ BUFFER parameter list will be returned during
the DATA- IN phase of the command. When transferring
data, the total data transfer will be split into smaller
bursts with a maximum size. The maximum burst size (the
maximum
amount
nects/disconnects) is controlled by the Maximum Burst
Size parameter set up by the MODE SELECT command.
If disconnection is allowed, the Drive disconnects when
executing this command.
19.2. Command Descriptor Block
6
5
READ BUFFER Command Descriptor Block
19 -1
Tandberg SLR Product Line SCSI Functional Specifications
of
data
transferred
4
3
RESERVED
Mode
between
recon-
2
1
0
Need help?
Do you have a question about the SLR7-140 PROGRAMMER and is the answer not in the manual?
Questions and answers