BYTE
BIT 7
n+0
Parameter Code = 0005h
n+1
n+2
DU
n+3
Parameter Length = 04h
n+4
Cartridge Write Pass Counter
n+7

Table 13-56: Cartridge Write Pass Counter Log Parameters

Parameter Code
DU
DS
TSD
ETC
TMC
LBIN
LP
Parameter Length
Cartridge Write
Pass Counter
Tandberg Data
Cartridge Write Pass Counter Log Parameters
6
5
DS
TSD
The Parameter Code is set to 0005h.
The Disable Update (DU) bit is not defined for List
Parameters (indicated by the LP bit) and is set to 0.
(Note: This bit can not be changed by the initiator)
The Disable Save (DS) bit is set to 1 to indicate that
the Drive does not support saving of this log parameter
in response to a LOG SELECT or LOG SENSE command with an
SP bit of 1.
(Note: This bit can not be changed by the initiator)
The Target Save Disable (TSD) bit is set to 0. The Drive
will save this list parameter on the medium for each
write operation.
(Note: This bit can not be changed by the initiator)
The Enable Threshold Comparison (ETC) bit is not defined
for List Parameters (indicated by the LP bit) and is set
to 0.
(Note: This bit can not be changed by the initiator)
The Threshold Met Criteria (TMC) field is not defined
for List Parameters (indicated by the LP bit) and is set
to 0.
(Note: This bit can not be changed by the initiator)
The LBIN bit is set to 1 to indicate that the List Pa-
rameter contains binary information.
(Note: This bit can not be changed by the initiator)
The List Parameters (LP) bit is set to 1 to indicate
that the parameter is a List Parameter.
(Note: This bit can not be changed by the initiator)
This field is set to 04h to indicate that the counter is
4 bytes wide.
The Write Pass Counter is incremented each time the
medium is written from BOP. Each partition has a
separate Write Pass Counter and this page will return
the counter of the current partition.
Any attempt by initiator to alter this parameter value
will be ignored.
13-60
Tandberg SLR Product Line SCSI Functional Specifications
4
3
ETC
TMC
Log Sense
2
1
0
LBIN
LP

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SLR7-140 PROGRAMMER and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Slr7Slr50Slr60Slr75Slr100Slr140

Table of Contents