Phase Sequencing - Tandberg Data SLR7-140 PROGRAMMER Manual

Scsi interface functional specification
Table of Contents

Advertisement

<sequence 1>
<sequence 2>
<sequence 3>
<sequence 4>
Tandberg Data

31.11. Phase Sequencing

In this section the possible SCSI-bus phase sequences
during execution of the command are described. Section
3.2.1 has more details about the generic phases in the
brackets.
:=
<initiator-part> <message-out> command> <disconnect> <reconnect>
<completed>
This sequence will be used when the specified transfer
length in the WRITE BUFFER command is zero.
:=
<initiator-part> <message-out> <command> <disconnect>
{<reconnect> <data-out> <disconnect>} <reconnect> <completed>
This sequence will be used when the transfer length is
greater than zero in the WRITE BUFFER command.
The Drive will disconnect when the number of data bytes
just transferred equals the number of bytes specified by
the Maximum Burst Size field in MODE SELECT command. The
Drive
will
then
another burst with a maximum size again controlled by
the Maximum Burst Size.
:=
<initiator-part> <message-out> command> <completed>
This sequence will be used when the specified transfer
length
in
the
disconnection is not allowed.
:=
<initiator-part> <message-out> <command> <data-out> <completed>
This sequence will be used when the transfer length is
greater than zero and disconnection is not allowed.
31-7
Tandberg SLR Product Line SCSI Functional Specifications
reconnect
immediately
WRITE
BUFFER
command
Write Buffer
to
transfer
is
zero
and

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SLR7-140 PROGRAMMER and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Slr7Slr50Slr60Slr75Slr100Slr140

Table of Contents