Exception Handling; Phase Sequencing - Tandberg Data SLR7-140 PROGRAMMER Manual

Scsi interface functional specification
Table of Contents

Advertisement

Tandberg Data
Request Sense

23.6. Exception Handling

The
REQUEST
SENSE
command
will
return
the
CHECK
CONDITION status only to report fatal errors for the
REQUEST SENSE command. Fatal errors are: non-zero bit in
command descriptor or parity error on the data bus.

23.7. Phase Sequencing

In this section the possible SCSI-bus phase sequences
during execution of the command are described. Section
3.2 has more details about the generic phases in the
brackets.
<sequence 1>
:=
<initiator-part> <message-out> <command> <data-in> <completed>
The
Drive
will
never
disconnect
when
executing
this
command.
23-8
Tandberg SLR Product Line SCSI Functional Specifications