Table 14-23:
PS
Page Code
Page Length
Forced Streaming
Count
Tandberg Data
14.3.10. Miscellaneous Parameters Page
This page is used to change values of several vendor
unique parameters.
The page can be saved.
6
5
R
Page Code = 20h
AEPU
RESERVED
Miscellaneous Page Descriptor
The Parameter Savable (PS) bit must be set to zero.
The Page Code for this page must be set to 20h.
The Page Length field must always be set to 10h.
The Forced Streaming Count field indicates if the Drive
will rewrite the last block to force streaming instead
of enter underrun mode and stop the tape when waiting
for more data from the Initiator.
A value of zero indicates that the Drive will enter
underrun mode when the Drive's data buffer becomes empty
during the write operation.
A value different from zero indicates that the Drive
will rewrite the last block before entering the underrun
mode. The maximum number of rewrites is specified by the
Forced Streaming Count field. If a track boundary is
encountered, the forced streaming will stop.
Legal values are numbers in the range 0..65535.
The default (factory programmed) value is 1024 for
SLR50 drives. The default (factory programmed) value
is 0 for SLR140, SLR100, SLR75, SLR60 and SLR7
drives.
14-29
Tandberg SLR Product Line SCSI Functional Specifications
4
3
EOWR
R
BSYI
R
CLN
Mode Select
2
1
0
BSYA
FAST
OND
TIN