BYTE
BIT 7
00
Peripheral Qualifier
01
Page Code = 82h
02
RESERVED
03
Page Length = 14h
04
ASCII Operation Definition Description Length = 13h
05
ASCII Operating Definition
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
End Of String = 00h
Table 9-6:
Peripheral Qualifier
Peripheral Device
Type
Page Code
Page Length
ASCII Operating
Definition
Description Length
ASCII Operating
Definition
Tandberg Data
9.3.2.4.
ASCII Implemented Operating Definition
6
5
ASCII Implemented Operating Definition Page
This field will normally be set to zero. When an
Unsupported LUN condition exists (if an IDENTIFY message
is received, the LUN field in the Command descriptor
block will be ignored and only the LUN field in the
IDENTIFY message will be evaluated.), this field will,
however, be set to 3.
This field is normally set to 1. When an Unsupported LUN
condition exists , this field will, however, be set to
1Fh.
This field will be set to the value of the Page Code
field in the Command Descriptor Block.
This field specifies the length in bytes of the
parameters that follow the Page Length field.
This field specifies the length in bytes of the
Following ASCII string (trailing 00h character
included).
This field holds the string " SCSI-2 X3.131-1994" .
9-9
Tandberg SLR Product Line SCSI Functional Specifications
4
3
2
Peripheral Device Type
"S"
"C"
"S"
"I"
"-"
"2"
" "
"X"
"3"
"."
"1"
"3"
"1"
"-"
"1"
"9"
"9"
"4"
Inquiry
1
0
Need help?
Do you have a question about the SLR7-140 PROGRAMMER and is the answer not in the manual?
Questions and answers