Power On Selftest (Post) Error Handling; Commands Executed After Post Error - Tandberg Data SLR7-140 PROGRAMMER Manual

Scsi interface functional specification
Table of Contents

Advertisement

No Tape Edge
Found
No Cartridge
Not Loaded
Sensor Error
Tape Runout
Tandberg Data
An
error
has
been
System. Media Access commands will be terminated with
CHECK CONDITION status. The Error Code will be set to
C
.
ARTRIDGE FAULT
No cartridge is inserted or the cartridge was removed
during command execution. Media Access commands will be
terminated with CHECK CONDITION status. The Error Code
will be set to M
EDIUM NOT PRESENT
DURING COMMAND EXECUTION
The
cartridge
has
command or by the AutoLoad function. The Error Code will
be set to L
OGICAL UNIT NOT READY
(LOAD/UNLOAD with the Load bit set to one) or L
IS IN THE PROCESS OF BECOMMING READY
AutoLoad is under execution).
An error has been detected in the Tape Hole Sensor
System. Media Access commands will be terminated with
CHECK CONDITION status. The Error Code will be set to
C
.
ARTRIDGE FAULT
The tape has run out on one of the cartridge reels.
Media
Access
commands
CONDITION status. The Error Code will be set to C
.
FAULT
7.5.

Power On Selftest (POST) Error Handling

The
Drive
executes
Power
On
and
failures. How the Drive reacts after detection of a
Power On Selftest (POST) error depends on which command
the initiator wants to execute. Some commands will be
executed as normal, others will be terminated.
The first REQUEST SENSE command issued after Power On
will return sense data for UNIT ATTENTION since UNIT
ATTENTION
has
priority
REQUEST SENSE command issued after a command terminated
because of POST failure will return sense data for this
POST
failure.
All
return sense data for the command previously executed,
normally NO SENSE.
If
the
Power
On
failure,
the
amber
sequence
(i.e.
initiated and successfully executed. The Amber Led will
not be cleared by drive Reset. Successful execution of
the
POST
sequence
information
and
again.
7.5.1.

Commands Executed After POST Error

The following commands will be executed as normal after
detection of a POST error.
REQUEST SENSE
INQUIRY
SEND DIAGNOSTICS
RECEIVE DIAGNOSTICS
7-8
Tandberg SLR Product Line SCSI Functional Specifications
detected
in
or M
.
not
been
loaded
,
INITIALIZING COMMAND REQUIRED
(a LOAD/UNLOAD command or
will
be
Power
On
Selftests
microcode
download,
over
all
other
REQUEST
SelfTest
(POST)
LED
will
flash
POST
or
SEND
DIAGNOSTICS
will
also
clear
all
commands
will
General Exception Handling
the
Tape
Head
,
EDIUM NOT PRESENT
by
a
LOAD/UNLOAD
OGICAL UNIT
terminated
with
ARTRIDGE
(POST)
and
may
other
errors.
SENSE
commands
sequence
reports
until
a
Selftest
command)
the
POST
failure
execute
as
Serve
REMOVED
CHECK
during
detect
The
will
a
is
normal

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SLR7-140 PROGRAMMER and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

This manual is also suitable for:

Slr7Slr50Slr60Slr75Slr100Slr140

Table of Contents