12.
BYTE
BIT 7
00
Operation Code 4Ch
01
Logical Unit Number (LUN)
02
03
RESERVED
04
RESERVED
05
RESERVED
06
RESERVED
07
Parameter List Length
08
09
Control Byte
Table 12-1:
Log Select
12.1. Command Description
The LOG SELECT command is used to modify statistical
information related to the media and maintained by the
Drive or to activate surveillance thresholds to monitor
selected events in the Drive
The
log
information
related to drive use and write/read operations to/from
the magnetic tape.
The parameter list is transferred during the DATA OUT
phase of the command. If disconnect is allowed, the
Drive disconnects while the transferred parameters are
processed.
12.2. Command Descriptor Block
6
5
PC
RESERVED
LOG SELECT Command Descriptor Block
1
Note that the log counter updates are not necessarily synchronized
with
the
events
comparison can not be used to monitor drive actions with any great
amount of precision.
12-1
Tandberg SLR Product Line SCSI Functional Specifications
1
.
consists
4
3
RESERVED
that
they
monitor.
of
numerous
counters
2
1
PCR
This
means
that
threshold
0
SP
Need help?