Flag Number
Flag
Flag 39:
Diagnostics
Required
Tandberg Data
Severity
W
Table 13-23: Supported TapeAlert Flags
Each flag will be cleared to zero in the following
circumstances:
At drive power on
When the TapeAlert Log page is read.
When specified corrective action has been taken (such as using a
cleaning cartridge)
On SCSI bus reset or Bus Device Reset Message
On Log Select reset
NOTE:
When a flag is cleared by reading the TapeAlert Log page, the
flag
will
not
be
removed (e.g. the specified corrective action has been taken).
All other methods of clearing allow the flag to be set again.
1
The
Media
Management
SLRtape100, SLRtape75, SLRtape60 or SLRtape40 media.
13-24
Tandberg SLR Product Line SCSI Functional Specifications
Cause
This flag is set to 1 when the Media Management algorithm
detects a drive with a dead channel. The drive will monitor the
channel performance and maintain a drive performance history
log in the media header. The algorithm is executed each time
the media header is updated (i.e. after a REWIND or LOAD/-
UNLOAD command). Run extended diagnostics (e.g. Stand
Alone Diagnostics (SAD) test or Send Diagnostics) to verify
that the drive has a fault. The flag is internally cleared when
the media is ejected.
set
again
until
algorithm
is
only
Log Sense
the
error
condition
executed
on
SLRtape140,
1
is
Need help?
Do you have a question about the SLR7-140 PROGRAMMER and is the answer not in the manual?