Tandberg Data
31.7. Download Microcode with Offsets and Save
Mode (7)
In this mode the initiator may split the transfer of
microcode over two or more WRITE BUFFER commands. If the
last
WRITE
BUFFER
commands completes successfully, the microcode shall be
saved in a non-volatile memory space (a Flash EPROM).
The downloaded code will then be effective after each
power-cycle and reset until it is supplanted in another
Download Microcode and Save Mode or Download Microcode
with Offsets and Save Mode operation.
When the Drive detects the receipt of the last WRITE
BUFFER command with mode 7, the Drive shall perform
verification of the complete set of the microcode prior
to
returning
GOOD
(refer to the Microcode Verification and Save section
later in this chapter).
Note that the transferred microcode will be lost after a
power-cycle or reset as long as it has not been saved.
To ensure that the microcode is not corrupted by another
SCSI command, it is recommended that either the WRITE
BUFFER commands are linked or that the Drive is reserved
by using the RESERVE command. Note that the last WRITE
BUFFER command in Mode 7 must be issued with Link Bit
equal 0.
31.8. Microcode Verification and Save
Before
saving
any
several tests on the microcode data to make sure that
the data really are microcode data intended for the
Drive.
The Microcode Version field must match the Drive's
version identifier located in the Drive Flash PROM.
This
prevents
microcode version of the Drive.
The
Mainboard
Header must be higher or equal the Mainboard Revision
in the Mainboard. This prevents the possibility of
saving microcode meant for a different hardware.
The Microcode ECC check must be correct.
If any of these tests fails the WRITE BUFFER command
will be terminated with a CHECK CONDITION status. The
microcode
in
the
current microcode is left unchanged.
If
the
disconnection
disconnect from the SCSI-bus before the save operation.
When the save operation has completed successfully, the
Drive will reconnect to the Initiator and send GOOD
status.
If disconnection is not allowed and the verification of
the code was passed through, the drive will give GOOD
status before the save operation is executed.
31-4
Tandberg SLR Product Line SCSI Functional Specifications
command
of
a
set
status
and
saving
microcode
the
the
possibility
Revision
located
data
buffer
is
is
allowed,
Write Buffer
of
one
or
more
the
microcode.
Drive
will
perform
of
changing
in
the
Microcode
not
saved
and
the
Drive
will
the
the