Cisco VS-C6509E-S720-10G User Manual page 436

User guide
Table of Contents

Advertisement

C65/76M Alarms
Table 8-2
Trap/Varbind
vtpVersionOneDevice
Detected
risingAlarm
fallingAlarm
All other traps
The following SNMP traps do not generate CEMF alarms:
ciscoFlashCopyCompletionTrap
ciscoFlashMiscOpCompletionTrap
ciscoConfigManEvent
tcpConnectionClose
stpxInconsistencyUpdate
moduleUp
moduleDown
chassisAlarmOn
chassisAlarmOff
vlanTrunkPortDynamicStatusChange
vtpVersionOneDeviceDetected
risingAlarm
failingAlarm
If these traps are received by the C65/76M software, they are ignored.
Several C65/76M alarms are generated based on the clogMessageGenerated SNMP trap. This trap is
generated by the CISCO-SYSLOG-MIB whenever a syslog message is recorded into the message table.
The severity of the CEMF alarm is based on the clogHistSeverity varbind value in the trap.
If a coldStart trap is received by the C65/76M software whose IP address corresponds to the IP address
of a Network Element object that is currently in the decommissioned state, then that object is
automatically commissioned. When the Network Element is commissioned, a subchassis discovery is
executed automatically. If the Network Element is populated with other C65/76M objects, and if there
is a mismatch between the type of C65/76M object and the type that is discovered, the object is placed
into the mismatched state and a corresponding alarm is raised against that object (see the
Alarms" section on page
The linkUp/linkDown SNMP traps signify that the operational status of a particular interface has
transitioned into or out of the down state. If a linkUp trap is received, it will clear any linkDown alarm
on the corresponding interface, if it exists.
If any other SNMP trap that is not listed in
informational alarm is raised against the Network Element object. The details for this trap (enterprise
and varbinds) is logged in the C6576MCntrllr.log file.
Cisco 6500/7600 Series Manager User Guide
8-8
CEMF Alarms Generated by SNMP Traps (continued)
Message
N/A
N/A
C6576M:0134_0 Unknown trap
received from switch. Check the
controller log file for details.
8-9).
Chapter 8
Alarm Severity Object
N/A
N/A
Informational
Table 8-2
is detected by the C65/76M software, then a general
Alarms and Alarm Management
Alarms
Cleared
N/A
N/A
N/A
N/A
Network
None
Element
"Object State

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents