Sign In
Upload
Manuals
Brands
MICRO-EPSILON Manuals
Measuring Instruments
optoCONTROL 2700
MICRO-EPSILON optoCONTROL 2700 Manuals
Manuals and User Guides for MICRO-EPSILON optoCONTROL 2700. We have
3
MICRO-EPSILON optoCONTROL 2700 manuals available for free PDF download: Operating Instructions Manual, Quick Manual
MICRO-EPSILON optoCONTROL 2700 Operating Instructions Manual (98 pages)
Brand:
MICRO-EPSILON
| Category:
Industrial Equipment
| Size: 11 MB
Table of Contents
Table of Contents
3
Safety
7
Symbols Used
7
Warnings
7
Notes on Product Marking
7
CE Marking
7
UKCA Marking
7
Intended Use
8
Proper Environment
8
Functional Principle, Technical Data
9
Description
9
Functional Principle
9
Block Diagram
10
Functions
11
Operating Modes
11
Technical Data
13
Delivery
15
Unpacking, Included in Delivery
15
Storage
15
Installation and Assembly
16
General
16
Light Source and Receiver
16
Dimensions
16
Mounting on Mounting Rail
17
Free Mounting
19
Calibrated Measurement Distance, Measuring Fields
20
Electrical Connections
21
Light Source
21
Receiver
21
Connection Possibilities
23
Pin Assignment
24
Supply Voltage
25
Analog Output
25
Multifunction Input
26
Switching Output
26
RS422 Connection with USB Converter IF2001/USB
27
Synchronization
27
Leds on Receiver
28
Operation
29
Initial Operation
29
Control Via Ethernet
29
Requirements
29
Direct Connection to PC
29
PC with Static IP
29
PC with DHCP
30
Network
30
Access Via Ethernet
30
Video Signal
31
Light Correction
31
Video Signal, Edge Detection
32
Presets, Setups, Measurement Configuration Selection
34
Signal Quality
34
Save Settings
35
Setup Mode
35
Measurement Chart
36
Advanced Settings
38
Preliminary Remarks about the Setting Possibilities
38
Inputs
38
Synchronization
38
Input Level
38
Encoder
39
Overview
39
Interpolation
39
Effect of Reference Track
40
Set to Value
40
Reset Reference Marker
40
Assignment of Digital Inputs
40
Data Recording
41
Measuring Line Width
41
Data Acquisition
41
Measurement Program
41
Presets, Search Direction
41
Measurement Configuration
42
Search Direction and Sequence of Edges, Examples
42
Measurement Direction
44
Defining Segments
45
Measuring Rate
45
Data Recording
45
Frame Averaging
46
Counter Reset
46
Region of Interest
46
Edge Filter
47
Error Handling
47
Triggering for Data Acquisition
47
General
47
Triggering for Measured Value Acquisition
49
Example
49
Signal Processing
49
Inclination Correction
49
Calculation
50
Data Source, Parameters, Calculation Programs
50
Definitions
51
Averaging
52
General
52
Moving Mean
52
Recursive Average
53
Median
53
Post-Processing
54
Zeroing/Mastering
54
General
54
Zeroing/Mastering Procedure
55
Statistics
56
Data Reduction
58
Triggering for Measured Value Output
58
Outputs
58
Data Output RS422
58
Data Output Ethernet
59
Analog Output
60
Switching Outputs
61
General, Overview
61
Setting Limit Values
62
Switching Logic
62
Data Output
62
Ethernet Settings
63
System Settings
63
Web Interface Unit
63
Load & Save
63
Import & Export
64
Access Authorization, Login, Logout
65
System Settings
65
Resetting the Sensor
66
Light Source
66
Disclaimer
67
Service, Repair
68
Service & Repair
68
Decommissioning, Disposal
69
Factory Settings
70
Optional Accessories
71
ASCII Communication
73
General
73
General Commands
73
Help on Commands
73
Retrieve Sensor Information
74
Reply Type
74
Parameter Overview
74
Synchronization
74
Reset
75
Reset Counter
75
User Level
75
Changing to the "Professional" User Level
75
Changing to the "User" User Level
75
User Level Query
75
Setting the User Level on Restart (Standard User)
75
Changing the Password
75
Correction, Referencing
76
Light Correction
76
Light Correction Status
76
Printing the Correction Table
76
Deleting the Correction Table
76
Soiling Check
76
Soiling Status
76
Multifunction Inputs
77
Defining the TTL/HTL Input
77
Selecting the Multifunction Input Function
77
Triggering
77
Trigger Source
77
Effect of Triggering
77
Trigger Mode
77
Trigger Level
78
Software Trigger
78
Number of Measurement Values to be Output
78
Step Size
78
Encoder Trigger Minimum
78
Encoder Trigger Maximum
78
Encoder Settings
79
Encoder Interpolation
79
Encoder Reference Track
79
Setting Encoder Reference Track
79
Encoder Start Value
79
Maximum Value of Encoder
79
Resetting the Encoder Reference Track
79
Interface Setting
79
Ethernet Settings
79
Settings for Transmitting Measured Values Via Ethernet
80
Ethernet Count Method
80
Setting the RS422 Baud Rate
80
TCP Settings
80
Terminator
80
Parameter Management, Load/Save Settings
80
Basic Settings
80
Output of Changed Settings
81
Exporting Sensor Settings
81
Importing Sensor Settings
81
Factory Reset
81
Measurement Settings
81
Measurement
82
Selecting the Measuring Program
82
Edge Search Direction
82
Measurement Direction
82
Number of Expected Edges
83
Defining Segments
83
Setting the Measuring Rate
83
Frame Averaging
83
Range of Interest
83
Edge Filter
83
Outputting a Signal with the Edge Filter
83
List of Edge Filter Signals
84
Switching the LED on and off
84
Edit Measured Value
84
Tilt Correction
84
Computation, Computation Module, Averaging
84
List of Possible Calculation Signals, Computing Module
85
Statistic Signals
85
Statistic Signals Settings
85
Selecting Statistic Signals
85
Resetting Statistics
86
List of Possible Mastering Signals
86
Configuring the Master Signal
86
List of Configured Mastering Signals
86
Master Settings
86
Data Output
86
Digital Output Selection
86
Selecting the Interface for a Reduced Data Rate
87
Reducing Data Output
87
Error Handling
87
Selecting the Measured Values to be Output
87
Selecting Ethernet Signals
87
Signals for Ethernet Output
87
Information about the Output of Values Via Ethernet
88
Selecting RS422 Signals
88
Signals for RS422 Output
88
Information about the Output of Values Via RS422
88
Switching Output
88
Limit Value Type for Switching Outputs
88
Possible Signals for Error Outputs
88
Assigning the Error Output Signal
88
Setting the Upper (Overshooting)/Lower (Undershooting) Limit Value for the Switching Outputs
89
Limits for Overshooting/Undershooting of Switching Outputs
89
Switching Output Hold Period
89
Switching Behavior of Error Outputs
89
Analog Output
90
Selecting the Signal for the Analog Output
90
Possible Signals for Analog Output
90
Selecting the Output Range for the Analog Output
90
Scaling of the Analog Output
90
Selecting the Scaling Range for the Analog Output
90
Measurement Data Format
90
Transferring Measured Data to a Measurement Server Via Ethernet
90
Data Format RS422 Interface
91
Bit Structure
91
Description
92
Examples
92
Output Values, Data Type and Unit
93
Error Messages
94
Index
98
Advertisement
MICRO-EPSILON optoCONTROL 2700 Operating Instructions Manual (102 pages)
Brand:
MICRO-EPSILON
| Category:
Measuring Instruments
| Size: 10 MB
Table of Contents
Table of Contents
3
Safety
7
Symbols Used
7
Warnings
7
Notes on Product Marking
7
CE Marking
7
UKCA Marking
8
Intended Use
8
Proper Environment
8
Functional Principle, Technical Data
9
Description
9
Functional Principle
9
Block Diagram
10
Functions
11
Operating Modes
11
Technical Data
13
Delivery
15
Unpacking, Included in Delivery
15
Storage
15
Installation and Assembly
16
General
16
Light Source and Receiver
16
Dimensions
16
Attachment to Mounting Rail
17
Freestanding Mounting
19
Calibrated Measurement Distance
20
Electrical Connections
21
Light Source
21
Receiver
21
Connection Options
22
Pin Assignment
23
Supply Voltage
24
Analog Output
24
Multifunction Input
25
Switching Output
26
RS422 Connection with USB Converter IF2001/USB
27
Synchronization
28
Leds on Receiver
28
Operation
29
Initial Operation
29
Control Via Ethernet
29
Requirements
29
Direct Connection to PC
29
PC with Static IP
29
PC with DHCP
30
Network
30
Access Via Ethernet
31
Video Signal
32
Light Correction
32
Video Signal, Edge Detection
33
Presets, Setups, Measurement Configuration Selection
34
Setup Mode
36
Measurement Chart
36
Advanced Settings
38
Preliminary Remarks Concerning the Setting Options
38
Inputs
38
Synchronization
38
Input Level
38
Encoder
39
Overview
39
Interpolation
40
Effect of Reference Track
40
Set to Value
40
Reset Reference Marker
40
Digital Input Assignment
41
Data Recording
42
Measuring Line Width
42
Measuring Program
43
Search Direction and Edge Order, Examples
44
Measurement Direction
46
Defining Segments
47
Measuring Rate
48
Frame Averaging
48
Counter Reset
48
Region of Interest
49
Edge Filter
50
Error Handling
50
Triggering for Data Acquisition
51
General
51
Triggering for Measured Value Acquisition
53
Example
53
Signal Processing
54
Tilt Correction
54
Calculation
55
Data Source, Parameters, Computing Programs
55
Definitions
56
Averaging
57
General
57
Moving Average
58
Recursive Average
58
Median
59
Post-Processing
60
Zeroing/Mastering
60
General
60
Zeroing/Mastering Procedure
61
Statistics
62
Data Reduction
63
Triggering for Measured Value Output
64
Outputs
64
Data Output RS422
64
Data Output Ethernet
65
Analog Output
66
Switching Outputs
67
General, Overview
67
Setting Limit Values
68
Switching Logic
68
Data Output
68
Ethernet Settings
69
System Settings
70
Web Interface Unit
70
Load & Save
70
Import & Export
71
Access Authorization
72
Resetting the Sensor
73
Light Source
73
Disclaimer
74
Service, Repair
75
Decommissioning, Disposal
76
Factory Settings
77
Optional Accessories
78
ASCII Communication
80
General
80
General Commands
80
Help on Commands
80
Retrieving Sensor Information
81
Reply Type
81
Parameter Overview
81
Synchronization
82
Reset
82
Reset Counter
82
User Level
82
Changing to the "Professional" User Level
82
Changing to the "User" User Level
82
User Level Query
82
Setting the User Level on Restart (Standard User)
82
Changing the Password
83
Correction, Referencing
83
Light Referencing
83
Light Correction Status
83
Printing the Correction Table
83
Deleting the Correction Table
83
Soiling Check
83
Soilingstatus
84
Multifunction Inputs
84
Defining the TTL/HTL Input
84
Selecting the Multifunction Input Function
84
Triggering
84
Trigger Source
84
Effect of Triggering
85
Trigger Mode
85
Trigger Level
85
Software Trigger
85
Number of Measured Values to be Output
85
Step Size
85
Encoder Trigger Minimum
86
Encoder Trigger Maximum
86
Encoder Settings
86
Encoder Interpolation
86
Encoder Reference Track
86
Setting the Encoder Reference Track
86
Encoder Start Value
86
Maximum Encoder Value
86
Resetting the Encoder Reference Track
87
Interface Setting
87
Ethernet Settings
87
Settings for Transmitting Measured Values Via Ethernet
87
Ethernet Count Method
87
Setting the RS422 Baud Rate
87
TCP Settings
87
Terminating Resistor
88
Parameter Management, Load/Save Settings
88
Basic Settings
88
Output of Changed Settings
88
Exporting Sensor Settings
88
Importing Sensor Settings
88
Factory Reset
88
Measurement Settings
89
Measurement
90
Selecting the Measuring Program
90
Edge Search Direction
90
Measurement Direction
90
Number of Expected Edges
90
Defining Segments
91
Setting the Measuring Rate
91
Frame Averaging
91
Range of Interest
91
Edge Filter
91
Outputting a Signal with the Edge Filter
91
List of Edge Filter Signals
92
Switching the LED on and off
92
Edit Measured Value
92
Tilt Correction
92
Calculation, Computing Module, Averaging
92
List of Possible Calculation Signals, Computing Module
93
Statistic Signals
93
Statistics Signals Settings
93
Selecting Statistic Signals
93
Resetting Statistics
94
List of Possible Mastering Signals
94
Configuring the Master Signal
94
List of Configured Mastering Signals
94
Master Settings
94
Data Output
95
Digital Output Selection
95
Selecting the Interface for a Reduced Data Rate
95
Reducing Data Output
95
Error Handling
95
Selecting the Measured Values to be Output
95
Selecting Ethernet Signals
95
Signals for Ethernet Output
96
Information about the Output of Values Via Ethernet
96
Selecting RS422 Signals
96
Signals for RS422 Output
96
Information about the Output of Values Via RS422
96
Switching Output
96
Limit Value Type for Switching Outputs
96
Possible Signals for Error Outputs
97
Assigning the Error Output Signal
97
Setting the Upper (Overshooting)/Lower (Undershooting) Limit Value for the Switching Outputs
97
Limits for Overshooting/Undershooting of Switching Outputs
97
Switching Output Hold Period
98
Switching Behavior of Error Outputs
98
Analog Output
98
Selecting the Signal for the Analog Output
98
Possible Signals for Analog Output
98
Selecting the Output Range for the Analog Output
98
Scaling of the Analog Output
98
Selecting the Scaling Range for the Analog Output
99
Measurement Data Format
99
Transmission of Measurement Data to a Measured Value Server Via Ethernet
99
Data Format of RS422 Interface
100
Output Values, Data Type and Unit
100
Index
102
MICRO-EPSILON optoCONTROL 2700 Quick Manual (48 pages)
EtherNet/IP Laser micrometer
Brand:
MICRO-EPSILON
| Category:
Measuring Instruments
| Size: 2 MB
Advertisement
Advertisement
Related Products
MICRO-EPSILON confocalDT 2451
MICRO-EPSILON confocalDT 2461
MICRO-EPSILON scanCONTROL 25 BL Series
MICRO-EPSILON scanCONTROL 2500/BL
MICRO-EPSILON scanCONTROL 2510/BL
MICRO-EPSILON scanCONTROL 2910
MICRO-EPSILON scanCONTROL 2960BL
MICRO-EPSILON optoCONTROL 2600
MICRO-EPSILON optoControl 1200
MICRO-EPSILON optoControl 1201
MICRO-EPSILON Categories
Measuring Instruments
Accessories
Industrial Equipment
Controller
Security Sensors
More MICRO-EPSILON Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL