List Of Parameters (Zs-Ldc) - Omron ZS Command Reference Manual

Smart sensors non-procedual communication
Hide thumbs Also See for ZS:
Table of Contents

Advertisement

List of Parameters (ZS-LDC)

The following parameters can be obtained or set by DATASET or DATAGET command:
Unit No.
Data No.
0
0
12
14
24
26
18
19
20
32
1
0
2
0
2
13
14
37
38
39
3
0
1
2
Parameter
Setting range/Output range
Measurement mode
0: STANDARD
1: HI-RESO
2: HI-SPEED
3: HI-SENS
4: CUSTOM
Start position of area 1 0 to 639 (pix)
End position of area 1
0 to 639 (pix)
Start position of area 2 0 to 639 (pix)
End position of area 2
0 to 639 (pix)
Exposure time
2 to 200 (1 div: 0.1ms)
Number of additional
1 to 200
lines
Line skipping
0: OFF
1: ON
Meas. Cycle
112 to 20000 (us)
Head installation
0: DIFFUSE
1: REGULAR
LD power mode
0: Auto
1: Auto-scale
2: Fixed
Surface to be
0: Peak
controlled for light
1: 1st surface
amount
2: 2nd surface
3: 3rd surface
Lower limit of LD
0 to 800 (1 div: 0.1%)
power
Upper limit of LD
0 to 800 (1 div: 0.1%)
power
Incident level
0 to 4095 (tone)
(1st surface)
Incident level
0 to 4095 (tone)
(2nd surface)
Incident level
0 to 4095 (tone)
(3rd surface)
Measurement object
0: NORMAL
1: PCB
2: MIRROR
3: GLASS
4: THICK
5: GAP
6: CUSTOM
Glass thickness/Gap
0: Normal
mode
1: Film/Else
Glass thickness/Gap
0: STOP
mode
1: MOVE
List of Parameters (ZS-LDC)
Parameters for CUSTOM
mode
Non-procedural Communication Command Reference
Others
ZS-Series
7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zs seriesZs-ldcZs-hldcZs-mdcZs-dsu

Table of Contents