Parameter Tables 162 and 163 (Dithering, Valve 1, Valve 2)
Tables 162 and 163 have identical structures. As an example, Table 162 is explained
here for valve 1.
Register Name, Type
0
1
2
3
4
5
6
Product manual | Version: 1.1.0
Proportional Valve Module 2-3-4
Bits, Explana-
tion
DG_FREQ,
0 ... 15
UINT
Dither fre-
quency
DG_AMPL,
0 ... 15
UINT
Dither ampli-
tude
DG_RAMP_ON,
0 ... 15
UINT
Start up ramp
per ms
DG_RAMP_OFF,
0 ... 15
UINT
Shutoff ramp
per ms
DG_WAVEFORM,
0 ... 15
UINT
Dither signal
form
DG_AUTO_
0 ... 15
AMPL_ADJ,
Automatic
UINT
dither ampli-
tude adjust-
ment
DG_DC_
0 ... 15
CORRECTION,
Dither DC cor-
UINT
rection
Table 13: Parameter Table 162 (Dithering, Valve 1)
Value/Range
Description
(Default)
1 ... 250
Unit: Hz
(Default: 25)
0 ... 5000
n × 0.01 %
(Default: 1000)
One LSB corresponds to 0.01 % of the
nominal current.
0 ... 10000
n × 0.01 %
(Default: 1)
One LSB corresponds to 0.01 % of the
nominal current per ms.
Value 0 = ramp function deactivated
0 ... 10000
n × 0.01 %
(Default: 1)
One LSB corresponds to 0.01 % of the
nominal current per ms.
Value 0 = ramp function deactivated
0 (default)
Dither signal form: square wave
1
Dither signal form: sinusoidal
0
Automatic dither amplitude adjustment de-
activated
If the dither amplitude exceeds the valid op-
erating range, then the dither signal is sim-
ply limited ("chopped"). The dither signal
becomes asymmetrical in the process.
1 (default)
Automatic dither amplitude adjustment acti-
vated
If the dither amplitude exceeds the valid op-
erating range, then the dither amplitude is
automatically reduced so a reduced-ampli-
tude symmetrical dither signal is used.
0 (default)
Dither DC correction deactivated
1
Dither DC correction activated
The dither signal is filtered. The DC compo-
nent is then compared to the setpoint speci-
fication. In the event of deviations, this error
component can be tracked. The DC track-
ing is performed by a PID controller.
Functions