750-1632/000-100
4.4 Signal Processing
4.4.1 Setpoint Processing
4.4.1.1 Specifying the Setpoint in the Operating Mode with One Valve
Setpoint, Reference Coil Control
Valve 1
Valve 1
Valve 1
4.4.1.2 Specifying the Setpoint in the Operating Mode with Two Valves
Setpoint, Reference Coil Control
Valve n
Valve n
4.4.1.3 Specifying the Setpoint in the Operating Mode with Two Valves; Coil Control: Two
Coils, Unidirectional (3-Wire)
Setpoint, Reference Coil Control
Valve n
Product manual | Version: 1.1.0
Proportional Valve Module 2-3-4
Setpoint Range
One coil, unidirec-
0 ... +100 %
tional
One coil, bidirec-
−100 ... +100 %
tional
Two coils, unidirec-
−100 ... < 0 %
tional (3- and 4-wire)
0 ... +100 %
Setpoint Range
One coil, unidirec-
0 ... +100 %
tional
One coil, bidirec-
−100 ... +100 %
tional
Table 19: Operating Mode with Two Valves, Coil Control; Two Coils, Unidirectional (3-Wire)
Setpoint Range
Two coils, unidirec-
−100 ... < 0 %
tional (3-wire)
0 ... +100 %
Table 17: Operating Mode with One Valve
Control Value Range
Coil A
Coil B
0 ... +100 %
0 %
−100 ... +100 %
0 %
0 %
100 ... 0 %
0 ... 100 %
0 %
Table 18: Operating Mode with Two Valves
Control Value Range
0 ... +100 %
−100 ...+100 %
Control Value Range
Coil A+ / Coil B+
Coil A− / Coil B−
0 %
100 ... 0 %
0 ... 100 %
0 %
Functions
43