Application Status Bytes V1_Status (S1) And V2_Status (S2); Table 34 Application Status Bytes V1_Status (S1) And V2_Status (S2) - WAGO 750 Product Manual

Table of Contents

Advertisement

750-1632/000-100
Bit 7
PWR_EN

4.6.4 Application Status Bytes V1_STATUS (S1) and V2_STATUS (S2)

Bit 7
JOG_POS_
ACK
Legend
JOG_POS_ ACK
JOG_NEG_ACK
DITHER_ST
DI1
DI2
TEACH_ST
ON_ TARGET
READY
Product manual | Version: 1.1.0
Proportional Valve Module 2-3-4
Bit 6
Bit 5
PowerEnable:
0: Switch output stage off.
1: Switch output stage on.
This bit is also used to acknowledge errors. For this purpose, the
value must be changed from 1 to 0.
If the error is no longer present, then the falling edge causes all
channel-specific errors in the local bus status byte to be acknowl-
edged.
Table 34: Application Status Bytes V1_STATUS (S1) and V2_STATUS (S2)
Bit 6
Bit 5
JOG_NEG_
DITHER_ST
ACK
Confirmation of JOG_POS
Confirmation of JOG_NEG
Status of dither function:
0: dithering OFF
1: dithering ON
0: DI 1 logical OFF
1: DI 1 logical ON
0: DI 2 logical OFF
1: DI 2 logical ON
Status of the teach-in function:
0: Teach-in function is not active.
1: Teach-in function is active. The teach-in function is being exe-
cuted, has been executed successfully or was canceled due to an er-
ror.
If TEACH_ST = 0:
0: Setpoint is not reached.
1: Setpoint is reached.
If TEACH_ST = 1:
0: Teach-in function is being executed.
1: Teach-in function has been executed successfully.
0: Output stage is deactivated.
1: Output stage is activated.
Bit 4
Bit 3
Bit 2
Bit 4
Bit 3
Bit 2
DI1
DI2
TEACH_ST
Functions
Bit 1
Bit 0
Bit 1
Bit 0
ON_ TAR-
READY
GET
57