Setting List - IAI SW-4000M-PMCL User Manual

Monochrome line scan camera
Table of Contents

Advertisement

Settings List
Settings List
: Settings that can only be configured when image capture on the camera is stopped.
Item
a) Device Control
GenCP Version
Device Vendor Name
Device Model Name
Device Manufacturer Info
Device Version
Device ID
Device User ID
Device Scan Type
Device Temperature Selector
Device Temperature (Celsius)
Device Clock Selector
Device Clock Frequency
Device Serial Port BaudRate
Device Reset
b) Image Format Control
Pixel Format
Test Pattern
Binning Vertical
Binning Horizontal
Binning Horizontal Mode
c) Acquisition Control
Trigger Selector
Trigger Mode
Trigger Source
Trigger Activation
Trigger OverLap
Acquisition Line Rate
Exposure Mode
Exposure Time
d) Analog Control
1
*
Setting range depending on the Tap Geometry and CL Pixel Clock settings..
Setting range
Any
Linescan
Sensor, Sensor Board Bottom,
Interface Board Bottom, FPGA
Camera Link
84.82MHz, 63.39MHz,
42.41MHz, 31.70MHz
Baud 9600,
Baud 19200,
Baud 38400,
Baud 57600,
Baud 115200
Mono8 Mono10
Off, Monochrome,
GrayPattern, White
1, 2
1, 2
Sum, Average
Line Start
Off, On
CC1(Camera Link),
Hirose 12Pin(TTL)
Rising Edge,
Falling Edge
Off, ReadOut
66 to 10058
*1
Off, Timed,
Trigger Width
3 to 97
*1
— 34 —
Default value
Display/configure information related to
the device.
"JAI Ltd., Japan"
Display the manufacturer name.
SW-4000M-PMCL
Display the model name.
"See the possicilities"
Display the manufacturer information.
Display the device version.
Display the device ID.
Set the user ID for the camera.
Linescan
Display the scan type of the camera.
Sensor
Display the location of the temperature
sensor inside the camera.
Display the internal temperature (°C) of
the camera.
Camera Link
Select the camera clock.
42.41MHz
Select the clock frequency for the
camera.
Baud 9600
Select the baud rate for the camera's
serial board.
Reset the device.
Configure image format settings.
Mono8
Set the pixel format.
Off
Select the test image.
1
Set the number of pixels in the vertical
direction for which to perform binning.
Set the number of pixels in the Horizontal
1
direction for which to perform binning.
Sum
Set the addition process to be used
during horizontal Binning.
Configure image acquisition settings.
Line Start
Select the trigger operation.
Off
Select the trigger mode.
Select the trigger signal source.
Select the polarity of the trigger signal
Falling Edge
(Falling edge of
(i.e., location of signal at which trigger is
input signal)
applied).
Off
Select the trigger overlap operation.
10000
Set the line rate as a frequency. (unit: Hz)
Timed (control
Select the exposure mode.
via exposure
time)
97
Set the exposure time.
The maximum value when [Trigger Mode]
is set to [Off] varies depending on the
[Acquisition Line Rate Raw] value.
Configure analog control settings.
SW-4000M-PMCL
Description

Advertisement

Table of Contents
loading

Table of Contents