Spclk (Sensor Pixel clock): 149.92 ns (6.67 MHz)
pclk (Cameralink Pixel clock): 18.74 ns (53.36 MHz: SPCLK × 8)
Restrictions on trigger input periods and line rate conditions
As the first video signal triggered after the power is turned on or immediately after the trigger interval is
2 ms or higher is significantly affected by dark currents, we do not recommend using the first line at the
beginning for [Trigger Mode].

■ When [Exposure Mode] is [Timed]

Perform accumulation and scanning using triggers from an external source.
As the accumulation control is performed using the camera's internal counter, accumulation will not be
affected by trigger jitter.
In addition, accumulation control can be performed individually for ch1 and ch2.
• Trigger period: exposure time + 5.1 μs
• Shortest trigger period: 25.48 μs (20.38 μs exposure time)
Electronic shutter
• Variable range: 20.38 μs (1L) to 1.995 ms (individual ch1/ch2 control possible)
• Variable unit: 149.9 ns (1clk) (individual ch1/ch2 control possible)
TRIGGER
Exposure Active
(Sensor Video 1/8 tap)
LVAL
DATA
Spclk (Sensor Pixel clock): 149.92 ns (6.67 MHz)
pclk (Cameralink Pixel clock): 18.74 ns (53.36 MHz: SPCLK × 8)
Restrictions on trigger input periods and line rate conditions
As the first video signal triggered after the power is turned on or immediately after the trigger interval is
2 ms or higher is significantly affected by dark currents, we do not recommend using the first line at the
beginning for [Trigger Mode].
25.79 us (min)
1.37us ± 0.075 us
20.38 us to 1995 us
̶ 26 ̶
5.1 us to 1979.62 us
6 spclk
0.94 us ± 0.075 us
128 spclk
19.189 us
25.3 us
1024 pclk
19.189 us
WA-1000D-CL