The failed drive appears in the list of failed drives. If it does not, you should wait, and then run the
command again.
Depending on the drive type and capacity, it can take up to several hours for the drive
to appear in the list of failed drives.
• Determine whether SED authentication is enabled.
How you replace the disk depends on how the disk drive is being used. If SED authentication is
enabled, you must use the SED replacement instructions in the
Guide. These Instructions describe additional steps you must perform before and after replacing an
SED.
• Make sure the replacement drive is supported by your platform. See the
• Make sure all other components in the system are functioning properly; if not, you must contact
technical support.
About this task
Drive firmware is automatically updated (nondisruptively) on new drives that have non current firmware
versions.
When replacing several disk drives, you must wait one minute between the removal of each failed disk
drive and the insertion of the replacement disk drive to allow the storage system to recognize the
existence of each new disk.
Procedure
Replace the failed drive by selecting the option appropriate to the drives that your platform supports.
ONTAP 9 NetApp Encryption Power
NetApp Hardware
Universe.
67
Need help?
Do you have a question about the ASA C Series and is the answer not in the manual?