successfully:
metrocluster check lif show
4. Perform the switchback by using the
surviving cluster.
5. Verify that the switchback operation has completed:
The switchback operation is still running when a cluster is in the
cluster_B::> metrocluster show
Cluster
--------------------
 Local: cluster_B configured
Remote: cluster_A configured
The switchback operation is complete when the clusters are in the
cluster_B::> metrocluster show
Cluster
--------------------
 Local: cluster_B configured
Remote: cluster_A configured
If a switchback is taking a long time to finish, you can check on the status of in-progress baselines by
using the
metrocluster config-replication resync-status show
6. Reestablish any SnapMirror or SnapVault configurations.
== Step 8: Return the failed part to NetApp
Return the failed part to NetApp, as described in the RMA instructions shipped with the kit. See the
Return & Replacements
= Replacing a power supply - ASA C400
:icons: font
:relative_path: ./asa-c-400/
:imagesdir: /tmp/d20231020-12297-25s5m0/source/./asa-c-250/../media/
Replacing a power supply (PSU) involves disconnecting the target PSU from the
power source, unplugging the power cable, removing the old PSU and installing the
replacement PSU, and then reconnecting the replacement PSU to the power source.
• The power supplies are redundant and hot-swappable.
• This procedure is written for replacing one power supply at a time.
It is a best practice to replace the power supply within two minutes of removing it from
the chassis. The system continues to function, but ONTAP sends messages to the
console about the degraded power supply until the power supply is replaced.
198
metrocluster switchback
Configuration State
-------------------
Configuration State
-------------------
page for further information.
command from any node in the
metrocluster show
waiting-for-switchback
Mode
---------
switchover
waiting-for-switchback
state.:
normal
Mode
---------
normal
normal
state:
command.