Download Print this page

NetApp ASA C Series Install page 247

Advertisement

5. Log into SP/BMC over SSH using the IP address of any of the nodes listed in the output from the
previous step.
If your're using a console/laptop, log into the controller using the same cluster administrator
credentials.
Open an SSH session to every SP/BMC connection so that you can monitor progress.
6. Halt all nodes in the cluster:
system node halt -node * -skip-lif-migration-before-shutdown true -ignore
-quorum-warnings true -inhibit-takeover
For clusters using SnapMirror synchronous operating in StrictSync mode:
node halt -node * -skip-lif-migration-before-shutdown true
-ignore-quorum-warnings true -inhibit-takeover true -ignore
-strict-sync-warnings true
7. Enter y for each controller in the cluster when you see
halt node "cluster name-controller number"?
{y|n}:
8. Wait for each controller to halt and display the LOADER prompt.
9. Turn off each PSU or unplug them if there is no PSU on/off switch.
10. Unplug the power cord from each PSU.
11. Verify that all controllers in the impaired chassis are powered down.
= Move and replace hardware - ASA C800
:icons: font
:relative_path: ./asa-c-800/
:imagesdir: /tmp/d20231020-12297-25s5m0/source/./asa-c-250/../media/
Move the power supplies, hard drives, and controller module from the impaired
chassis to the new chassis, and swap out the impaired chassis with the new chassis
of the same model as the impaired chassis.
== Step 1: Remove the controller modules
To replace the chassis, you must remove the controller modules from the old chassis.
1. If you are not already grounded, properly ground yourself.
2. Release the power cable retainers, and then unplug the cables from the power supplies.
3. Loosen the hook and loop strap binding the cables to the cable management device, and then unplug
the system cables from the controller module, keeping track of where the cables were connected.
Leave the cables in the cable management device so that when you reinstall the cable management
device, the cables are organized.
4. Remove the cable management device from the controller module and set it aside.
5. Press down on both of the locking latches, and then rotate both latches downward at the same time.
true.
Warning: Are you sure you want to