key IDs of the authentication keys.
If the command fails, contact Customer Support.
◦ If the
Key Manager type
yes/true, use the
Manager type.
Use the security key-manager key query to verify that the
authentication keys.
11. Connect the console cable to the partner controller.
12. Give back the controller using the
13. Restore automatic giveback if you disabled it by using the
local -auto-giveback true
14. Restore Autosupport if it was disabled by using the
* -type all -message MAINT=END
= Return the failed part to NetApp - ASA C800
:icons: font
:relative_path: ./asa-c-800/
:imagesdir: /tmp/d20231020-12297-25s5m0/source/./asa-c-250/../media/
Return the failed part to NetApp, as described in the RMA instructions shipped with
the kit. See the
Part Return & Replacements
= Chassis
= Replace the chassis - ASA C800
:icons: font
:relative_path: ./asa-c-800/
:imagesdir: /tmp/d20231020-12297-25s5m0/source/./asa-c-250/../media/
To replace the chassis, you must move the bezel, controller modules, and NVMe
drives from the impaired chassis to the replacement chassis, and then remove the
impaired chassis from the equipment rack or system cabinet and install the
replacement chassis in its place.
All other components in the system must be functioning properly; if not, you must contact technical
support.
• You can use this procedure with all versions of ONTAP supported by your system.
• This procedure is written with the assumption that you are moving the bezel, NVMe drives, and
controller modules to the new chassis, and that the replacement chassis is a new component from
NetApp.
• This procedure is disruptive. For a two-node cluster, you will have a complete service outage and a
partial outage in a multi-node cluster.
= Shut down the controllers - ASA C800
:icons: font
=
and the
onboard
security key-manager onboard sync
storage failover giveback -fromnode local
command.
column = anything other than
Restored
command to re-sync the Key
Restored
column =
storage failover modify -node
system node autosupport invoke -node
page for further information.
yes/true
for all
command.
243