The login prompt
Waiting for giveback...
4. Move the console cable to the partner controller and give back the target controller storage using the
storage failover giveback -fromnode local -only-cfo-aggregates true local
command.
◦ If the command fails because of a failed disk, physically disengage the failed disk, but leave the
disk in the slot until a replacement is received.
◦ If the command fails because of an open CIFS sessions, check with customer how to close out
CIFS sessions.
Terminating CIFS can cause loss of data.
◦ If the command fails because the partner "not ready", wait 5 minutes for the NVMEMs to
synchronize.
◦ If the command fails because of an NDMP, SnapMirror, or SnapVault process, disable the
process. See the appropriate Documentation Center for more information.
5. Wait 3 minutes and check the failover status with the
6. At the clustershell prompt, enter the
interfaces that are not on their home controller and port.
If any interfaces are listed as false, revert those interfaces back to their home port using the
int revert -vserver Cluster -lif nodename
7. Move the console cable to the target controller and run the
ONTAP versions.
8. Restore automatic giveback if you disabled it by using the
local -auto-giveback true
9. Use the
storage encryption disk show
10. Use the
security key-manager key query
authentication keys that are stored on the key management servers.
◦ If the
Restored
replacement process.
◦ If the
Key Manager type
yes/true, use the
key IDs of the authentication keys.
If the command fails, contact Customer Support.
◦ If the
Key Manager type
yes/true, use the
net int show -is-home false
command.
column = yes/true, you are done and can proceed to complete the
=
external
security key-manager external restore
=
and the
onboard
security key-manager onboard sync
Go to Step 7.
a. Log into the partner controller.
b. Confirm the target controller is ready for
giveback with the
command.
show
storage failover show
command.
version -v
storage failover modify -node
at the clustershell prompt, to review the output.
command to display the key IDs of the
and the
Restored
column = anything other than
column = anything other than
Restored
storage failover
command.
command to list the logical
command to check the
command to restore the
command to re-sync the Key
net
129
Need help?
Do you have a question about the ASA C Series and is the answer not in the manual?