15. Move the console cable to the partner controller.
16. Give back the target controller using the
command.
17. Check the giveback status, 3 minutes after it reports complete, using the
command.
If giveback is not complete after 20 minutes, contact Customer Support.
18. At the clustershell prompt, enter the
interfaces that are not on their home controller and port.
If any interfaces are listed as false, revert those interfaces back to their home port using the
int revert -vserver Cluster -lif nodename
19. Move the console cable to the target controller and run the
ONTAP versions.
20. Restore automatic giveback if you disabled it by using the
local -auto-giveback true
== Option 2: Restore NSE/NVE on systems running ONTAP 9.5 and earlier
Steps
1. Connect the console cable to the target controller.
2. Use the
boot_ontap
3. Check the console output:
If the console
displays...
The login prompt
Waiting for giveback...
4. Move the console cable to the partner controller and give back the target controller storage using the
storage failover giveback -fromnode local -only-cfo-aggregates true local
command.
◦ If the command fails because of a failed disk, physically disengage the failed disk, but leave the
disk in the slot until a replacement is received.
◦ If the command fails because of an open CIFS sessions, check with customer how to close out
CIFS sessions.
Terminating CIFS can cause loss of data.
◦ If the command fails because the partner "not ready", wait 5 minutes for the NVMEMs to
synchronize.
240
storage failover giveback -fromnode local
net int show -is-home false
command.
command at the LOADER prompt to boot the controller.
Then...
Go to Step 7.
a. Log into the partner controller.
b. Confirm the target controller is ready for giveback with the
failover show
command.
version -v
storage failover modify -node
command.
storage failover show
command to list the logical
net
command to check the
storage
Need help?
Do you have a question about the ASA C Series and is the answer not in the manual?