NetApp ASA C Series Install page 303

Advertisement

2. Align the end of the controller module with the opening in the chassis, and then gently push the
controller module halfway into the system.
Do not completely insert the controller module in the chassis until instructed to do so.
3. Recable the system, as needed.
4. Plug the power cables into the power supplies and reinstall the power cable retainers.
5. Complete the reinstallation of the controller module:
a. Firmly push the controller module into the chassis until it meets the midplane and is fully seated.
The locking latches rise when the controller module is fully seated.
Do not use excessive force when sliding the controller module into the chassis to
avoid damaging the connectors.
The controller module begins to boot as soon as it is fully seated in the chassis.
b. Rotate the locking latches upward, tilting them so that they clear the locking pins, and then lower
them into the locked position.
c. If you have not already done so, reinstall the cable management device.
6. Return the controller to normal operation by giving back its storage:
-ofnode impaired_node_name
7. If automatic giveback was disabled, reenable it:
-auto-giveback true
== Step 5: Return the failed part to NetApp
Return the failed part to NetApp, as described in the RMA instructions shipped with the kit. See the
Return & Replacements
= Replace a power supply - ASA C800
:icons: font
:relative_path: ./asa-c-800/
:imagesdir: /tmp/d20231020-12297-25s5m0/source/./asa-c-250/../media/
Replacing a power supply (PSU) involves disconnecting the target PSU from the
power source, unplugging the power cable, removing the old PSU and installing the
replacement PSU, and then reconnecting it to the power source.
The power supplies are redundant and hot-swappable.
About this task
This procedure is written for replacing one PSU at a time.
It is a best practice to replace the PSU within two minutes of removing it from the chassis.
The system continues to function, but ONTAP sends messages to the console about the
degraded PSU until the PSU is replaced.
page for further information.
storage failover giveback
storage failover modify -node local