them into the locked position.
c. If you have not already done so, reinstall the cable management device.
== Step 5: Return the failed part to NetApp
Return the failed part to NetApp, as described in the RMA instructions shipped with the kit. See the
Return & Replacements
= Replace SSD Drive or HDD Drive - ASA C800
:icons: font
:relative_path: ./asa-c-800/
:imagesdir: /tmp/d20231020-12297-25s5m0/source/./asa-c-250/../media/
You can replace a failed drive nondisruptively while I/O is in progress. The procedure
for replacing an SSD is meant for non-spinning drives and the procedure for
replacing an HDD is meant for spinning drives.
When a drive fails, the platform logs a warning message to the system console indicating which drive has
failed. In addition, both the fault LED on the operator display panel and the fault LED on the failed drive
are illuminated.
Before you begin
• Follow best practice and install the current version of the Disk Qualification Package (DQP) before
replacing a drive.
• Identify the failed disk drive by running the
system console.
The failed drive appears in the list of failed drives. If it does not, you should wait, and then run the
command again.
Depending on the drive type and capacity, it can take up to several hours for the drive
to appear in the list of failed drives.
• Determine whether SED authentication is enabled.
How you replace the disk depends on how the disk drive is being used. If SED authentication is
enabled, you must use the SED replacement instructions in the
Guide. These Instructions describe additional steps you must perform before and after replacing an
SED.
• Make sure the replacement drive is supported by your platform. See the
• Make sure all other components in the system are functioning properly; if not, you must contact
technical support.
About this task
Drive firmware is automatically updated (nondisruptively) on new drives that have non current firmware
versions.
When replacing several disk drives, you must wait one minute between the removal of each failed disk
drive and the insertion of the replacement disk drive to allow the storage system to recognize the
existence of each new disk.
page for further information.
storage disk show -broken
command from the
ONTAP 9 NetApp Encryption Power
NetApp Hardware
Part
Universe.
275
Need help?
Do you have a question about the ASA C Series and is the answer not in the manual?