mechanisms snap into place.
The controller module begins to boot as soon as it is fully seated in the chassis. Be prepared to
interrupt the boot process.
The controller module should be fully inserted and flush with the edges of the chassis.
= Restore and verify the system configuration - ASA C250
:icons: font
:relative_path: ./asa-c-250/
:imagesdir: /tmp/d20231020-12297-25s5m0/source/./asa-c-250/../media/
After completing the hardware replacement and booting to Maintenance mode, you
verify the low-level system configuration of the replacement controller and
reconfigure system settings as necessary.
== Step 1: Set and verify system time after replacing the controller
You should check the time and date on the replacement controller module against the healthy controller
module in an HA pair, or against a reliable time server in a stand-alone configuration. If the time and date
do not match, you must reset them on the replacement controller module to prevent possible outages on
clients due to time differences.
About this task
It is important that you apply the commands in the steps on the correct systems:
• The replacement node is the new node that replaced the impaired node as part of this procedure.
• The healthy node is the HA partner of the replacement node.
Steps
1. If the replacement node is not at the LOADER prompt, halt the system to the LOADER prompt.
2. On the healthy node, check the system time:
The date and time are based on the configured timezone.
3. At the LOADER prompt, check the date and time on the replacement node:
The date and time are given in GMT.
4. If necessary, set the date in GMT on the replacement node:
5. If necessary, set the time in GMT on the replacement node:
6. At the LOADER prompt, confirm the date and time on the replacement node:
The date and time are given in GMT.
== Step 2: Verify and set the HA state of the controller
You must verify the
HA
system configuration.
54
state of the controller module and, if necessary, update the state to match your
cluster date show
set date mm/dd/yyyy
set time hh:mm:ss
show date
date
Need help?
Do you have a question about the ASA C Series and is the answer not in the manual?