Figure 102. Good Downstream Power Connection

11.4.4.

EMI Considerations

The following guidelines apply to the selection and placement of common-mode chokes and ESD
protection devices.
11.4.4.1.

Common Mode Chokes

Testing has shown that common-mode chokes can provide required noise attenuation. A design should
include a common-mode choke footprint to provide a stuffing option in the event the choke is needed to
pass EMI testing. Figure 103 shows the schematic of a typical common-mode choke and ESD
suppression components. The choke should be placed as close as possible to the USB connector signal
pins.

Figure 103. Common Mode Choke Schematic

Common mode chokes distort full-speed and high-speed signal quality. As the common mode
impedance increases, the distortion will increase, so you should test the effects of the common mode
choke on full speed and high-speed signal quality. Common mode chokes with a target impedance of 80
Ω to 90 Ω at 100 MHz generally provide adequate noise attenuation.
Finding a common mode choke that meets the designer's needs is a two-step process.
210
Thermister
5V
5V
5V Sus
Switch
220uF
Common Mode
Choke
D+
D -
ESD Supression
Components
V V c c c c
1 1
470pF
4 4
G G n n d d
V V c c c c
1 1
470pF
4 4
G G n n d d
Vcc
®
Intel
855GM/855GME Chipset Platform Design Guide
Port1
Port2
USB A
Connector
R