Selecting Test Features

Inserting an External PDH/DSn Payload/Test Signal

Inserting an External PDH/DSn Payload/Test Signal

Description
You can insert 2 Mb/s, 34 Mb/s or 140 Mb/s into an STM-N line signal when option
012 is fitted. DS3, DS1, E3 and E1 can be inserted when option 014 is fitted.
HOW TO:
Insert 34 Mb/s, DS3 & 140 Mb/s
1 Press
2 Set up the required transmit SDH interface, set appropriate MAPPING then
choose TU/VT PAYLOAD
as indicated on the instrument display (when you position the cursor on the
PAYLOAD TYPE field and select INSERT).
76
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
RATE
140 Mb/s
SDH Only
DS3
SDH & SONET
34Mb/s
SDH & SONET
2Mb/s
PDH, SDH & SONET
DS1
DSn, SDH & SONET
, select
TRANSMIT
SDH
INSERT 140 Mb/s
as required. Connect your external source to the appropriate port
INSERT DS3
Availability
Option
012
001, 012, 002
001, 012,002
001, 012, 002
001, 012, 002
and the
MAIN SETTINGS
INSERT 34 Mb/s
,
page.
or