Monitoring Signaling Bits - Agilent Technologies OmniBER 718 SDH User Manual

Table of Contents

Advertisement

Making Measurements

Monitoring Signaling Bits

Monitoring Signaling Bits

Description
The OmniBER 718 receiver can be used to monitor the state of signaling bits in
received 2 Mb/s signals with timeslot-16 CAS multiframing (PCM30 or
PCM30CRC) and DS1 structured signals.
2.048 Mb/s Results
For 2 Mb/s signals with timeslot-16 CAS multiframing a table showing the values of
A,B,C,D signaling bits in all 30 channels is given.
DS1 Results
D4 and SLC-96 payloads
A table simultaneously showing the state of the A and B signaling bits in the 6th and
12th frames of a superframe is given. Each frame contains 24 timeslots. In SLC-96
mode A and B choices are 0, 1 or alternating. If you set bit A or B to alternate, the
displayed bit changes to an A, to indicate that the bit is alternating from 1 to 0. The
same signaling is transmitted in all channels.
ESF Payloads
A table simultaneously showing the state of the A, B, C and D signaling bits in the
6th, 12th, 18th and 24th frames of a superframe is given. Each frame contains 24
timeslots.