Selecting Test Features
Using Transmit Overhead Setup
turn). The value of the bytes can be set using
If BYTE NAMES is chosen, the labels for the ALL COLUMNS overhead bytes
are displayed.
4 If POH (Path Overhead) is chosen, choose the TYPE of overhead within STM-1
under test to be setup.
J1 and J2 bytes can be set under Path Overhead or Trace Messages. H4 byte has
a choice of sequences for TU-12, TU11 and TU-2 mapping:
Full Sequence - 48 byte binary sequence.
Reduced Sequence - Binary count sequence of 0 to 3 i.e. 111111(00 to 11).
COC1 Sequence - Binary count sequence of 0 to 3 i.e. 110000(00 to 11).
5 If TRACE MESSAGES is chosen, see "Setting Overhead Trace Messages "
page 58.
N O T E
Any bit of an overhead byte which is displayed as x or s cannot be set at any time.
All other bits can be set to 0 or 1.
TIP:
You can set all overhead bytes to the default state by selecting SETUP
You can set all overhead bytes and test functions to the default state by recalling
Stored Settings [0] on the
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
INCREASE DIGIT
OTHER
DECREASE DIGIT
.
display.
.
DEFAULT
55