Selecting and Using "Other" Features

MS-REI Result/Enable

MS-REI Result/Enable

Before running a test, you can choose to enable or disable the SDH measurement of
MS-REI or the equivalent SONET measurement of
REI-L.
This function is available on the
OTHER
display.
MISCELLANEOUS
HOW TO:
1 Choose MS-REI ENABLE
or
as required.
ON
OFFN
When set to OFF, the MS-REI and REI-L measurements are suppressed.
Cumulative, Short Term and Analysis measurements are affected alike.
The MS-REI measurement is twinned with B2-BIP with regard to the G.826 PUAS
measurement. This results in the B2-BIP PUAS measurement showing N/A when
MS-REI is set to OFF.