Setting the Interfaces

Setting PDH/DSn Receive Interface (Option 012)

Setting PDH/DSn Receive Interface
(Option 012)
Description
PDH Receive interface settings should match the network equipment settings of
Rate, Termination and Line Code and determine the Payload to be tested.
TIP:
To set the transmitter and receiver to the same interface settings choose
SETTINGS CONTROL COUPLED
HOW TO:
1 Choose the required SIGNAL rate.
2 If you have chosen 2 Mb/s as the SIGNAL rate, choose the required
TERMINATION. (At all other rates the impedance is fixed.)
3 If you have chosen 2 Mb/s, DS1 or 8 Mb/s as the SIGNAL rate, choose the
required LINE CODE. (At 34Mb/s, 140 Mb/s and DS3 coding is fixed.)
4 If you are measuring at the network equipment monitor point, set the LEVEL
field to
normal level.
Choose the GAIN required to return the received signal to normal.
Choose EQUALIZATION
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
.
. In this case the received signal will be 20 to 30 dB below the
MONITOR
to compensate for cable losses if required.
ON
OTHER
47