Selecting Test Features
Generating Automatic Protection Switch (APS) Messages
ACTIVE APS
The ACTIVE APS message type gives real-time response to provide switching
Message Type
keep-alive capability. The instrument will not initiate any changes, but will respond
to change requests that appear on the input K1/K2 byte values.
The ACTIVE APS message type offers two modes:-
• UNIDIRECTIONAL
• BIDIRECTIONAL
The behaviour for each mode is as shown in the following table.
APS MODE
UNIDIRECTIONAL
BIDIRECTIONAL
BIDIRECTIONAL
*
ITU bit numbering convention
where:
xxxx = any 4-bit binary value.
user = user programmable bit, corresponding to APS ARCHITECTURE.
yyyy = any non-zero 4-bit binary value.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Insert sdh_aps2.bmp
RX K1
TX K1
TX K1
*
*
(b5-b8)
(b1-b4)
(b5-b8)
xxxx
0000
0000
0000
0000
0000
yyyy
0010
yyyy
TX K2
TX K2
TX K2
*
*
*
(b1-b4)
(b5)
(b6-b8)
xxxx
user
100
0000
user
101
yyyy
user
101
101
*