Agilent Technologies OmniBER OTN J7232A Technical Data Sheet
Agilent Technologies OmniBER OTN J7232A Technical Data Sheet

Agilent Technologies OmniBER OTN J7232A Technical Data Sheet

Communications performance analyzers, powerful sonet/sdh testers, ideal for testing next generation sonet/sdh devices and modules
Hide thumbs Also See for OmniBER OTN J7232A:

Advertisement

Quick Links

Agilent Technologies
OmniBER OTN
Communications
Performance Analyzers
J7232A & J7230B
Technical Data Sheet
Powerful SONET/SDH testers, ideal for
testing next generation SONET/ SDH
devices and modules.

Advertisement

Table of Contents
loading

Summary of Contents for Agilent Technologies OmniBER OTN J7232A

  • Page 1 Agilent Technologies OmniBER OTN Communications Performance Analyzers J7232A & J7230B Technical Data Sheet Powerful SONET/SDH testers, ideal for testing next generation SONET/ SDH devices and modules.
  • Page 2 • ITU-T G.7041 GFP (Generic Framing Introduction Procedure) compliance testing (GFP-T and GFP-F) Agilent Technologies' new OmniBER OTN • ITU-T X.86 LAPS (Link Access J7232A and J7230B are not only powerful Procedure for SDH) compliance testing SONET/SDH testers, they are ideal for testing next generation SONET/ SDH •...
  • Page 3: Table Of Contents

    OmniBER OTN Communications Performance Analyzers Contents SmartTest Additional measurements Signal Wizard Signal Wizard (all-channel testing) GFP Testing (ITU-T G.7041) Error and alarm generation LAPS Testing (ITU-T X.86)5 Error generation Ethernet MAC Testing Alarm generation SONET/SDH Virtual Concatenation Overhead testing SONET/SDH testing OTN overhead testing Contiguous Concatenations enhancement SONET/SDH overhead testing...
  • Page 4: Smarttest

    OmniBER OTN Communications Performance Analyzers • Ability to inject and detect erroneous SmartTest GFP Testing (ITU-T G.7041) frame alarms and link loss The OmniBER OTN allows structured test The front panel Smart Test key provides • User programmable header fields signals to be generated in order to fully test fast access to the test set's extensive allows other HDLC-based...
  • Page 5: Sonet/Sdh Virtual Concatenation

    OmniBER OTN Communications Performance Analyzers DSn/PDH testing SONET/SDH Virtual • Service disruption test Concatenation • Setup and monitoring for linear and The DSn/PDH test capability allows ring APS/MSP messages comprehensive testing of DSn/PDH Verify virtual concatenation of high and • Active APS test signals and networks with the following low order payloads with delay generation interfaces: DS1 (1.5 Mb/s), DS3 (45...
  • Page 6: Instrument Tour

    OmniBER OTN Communications Performance Analyzers Instrument Tour Figure 3. bright bi-color LEDs show test status at a large active-matrix glance (TFT) color display SmartTest - the gateway to powerful test tools help system at the touch of a button simple operation via menu and arrow navigation keypad for text and...
  • Page 7 OmniBER OTN Communications Performance Analyzers Instrument Tour (continued) STS-1/3 and STM-0/1e Tx Eye clock 52-2488Mb/s Tx and Rx Tx Data 10 Gb/s optical Rx Tx Eye clock 10/10.71 Gb/s 52/155/622/2488 Mb/s optical TX (1310nm) 52/155/622/2488 Mb/s RX data optical TX (1550nm) eye clock for 52-2488 10 Gb/s optical Tx Mb/s optical Tx...
  • Page 8: Technical Specifications

    OmniBER OTN Communications Performance Analyzers Technical specifications OmniBER OTN J7232A & J7230B Optical transmitters The following specification provides details on the OmniBER OTN 52Mb/s - 2.5Gb/s 10Gb/s & 10.71Gb/s transmission test set, including all standard options. Where required, contact your Agilent sales representative for information regarding Line Code availability of these enhanced testing products.
  • Page 9: Sonet/Sdh Electrical Interfaces

    OmniBER OTN Communications Performance Analyzers SONET/SDH Electrical interfaces (supplied with options Clock synchronization (inputs, outputs, line frequency 104, 105 and 106) offset) Internal: ± 4.5 ppm Includes setting accuracy, STS-1/3 andSTM-0/1e Clock references stability over temperature and aging. External Clock Inputs: Transmitter Meets Telcordia GR-253-CORE Issue 3 and BITS (1.5 Mb/s): Bantam (100Ω...
  • Page 10: Signal Structures, Mappings And Payloads

    OmniBER OTN Communications Performance Analyzers Signal Structures, Mappings and Payloads OTN mappings Synchronous and asynchronous mapping of 10 Gb/s SONET/SDH structured payloads is supported plus test signal and null client mappings as per ITU-T G.709. For SONET/SDH payloads, both synchronous and asynchronous mappings are supported. In asynchronous mode, the payload offset and line rate offset can be applied to the transmitted signal and measured by the instrument receiver.
  • Page 11: Sdh Mappings

    OmniBER OTN Communications Performance Analyzers SDH mappings Bulk AU-3, AU-4, AU-4-Nc, TU mappings and DSn/En service mappings supplied as standard with the product. Ethernet mappings support GFP (Framed and transparent) and LAP-S within virtually concatenated AU-4-xv, AU-3-xv, TU-3-xv, TU-12-xv, TU-11-xv or AU-3, AU-4, AU-4-2c, AU-4-3c, AU-4-8c. Virtual Concatenation mappings Mapping No.
  • Page 12: Mixed Mappings Generation (Requires Option 325)

    OmniBER OTN Communications Performance Analyzers Mixed mappings generation (requires option 325) The OmniBER OTN can easily generate a SONET/SDH test signal containing any valid combination of supported STS/AU containers. An example is shown in Figure 8 below: With a mixed mapping configuration, one channel is selected as the foreground/test channel on the instrument transmitter. This test channel can be a virtually concatenated signal.
  • Page 13: Dsn/Pdh Frame Formats And Channel Structures

    OmniBER OTN Communications Performance Analyzers Measurements DSn/PDH frame formats and channel structures Supports generation and analysis of framed, channel structured Error measurements (mux/demux) and unframed test signals. Manual, single, timed start. Measurement Signal Framing Channel structures control SF (D4), ESF, SLC-96, 56 kb/s, 64 kb/s, n x Error count, error ratio.
  • Page 14: Alarm Detection And Measurement

    OmniBER OTN Communications Performance Analyzers Alarm detection and measurement Additional measurements Alarm seconds provided for all supported alarms. Supported for all optical receive rates. Results Optical power Ranges: 10/10.71 Gb/s: -3dBm to -25 dBm. Front panel LEDs: Alarm LEDs 52Mb/s, 155Mb/s, 622Mb/s, 2.5 Gb/s: -3 dBm to Red/green: Signal, frame (all levels of framing), errors -28 dBm.
  • Page 15: Signal Wizard (All-Channel Testing)

    OmniBER OTN Communications Performance Analyzers Signal Wizard (all-channel testing) Overview of received path trace messages: Path routing test facilities • Tabular display showing the J1 path trace OTN: OTU2 message associated with each STS/AU channel Line rates in the received line signal. SONET: OC-1/3/12/48/192, STS-1/3 SDH: STM-0/1/4/16/64o, STM-0/1e •...
  • Page 16: Error And Alarm Generation

    OmniBER OTN Communications Performance Analyzers Error and alarm generation 2. For OC-192/STM-64, supports both the 'M1 only' and 'M0+M1' options of the standards. 3. Not supported for data, frame, MFAS BPV/code, FEC block or bit. 4. The maximum error rate for any error type is 1 x 10 or the maximum Error generation error rate supported by the error type (its saturation value), whichever is...
  • Page 17: Overhead Testing

    OmniBER OTN Communications Performance Analyzers Overhead testing Four complete optical channel frames including Frame Capture overhead, payload and FEC blocks can be captured for display and analysis. Frame Capture Triggers: OTN overhead testing Trigger Selection: • Manual - Four frames after the manual trigger are Overhead bytes are user programmable in Overhead captured.
  • Page 18: Gfp Overhead Testing

    OmniBER OTN Communications Performance Analyzers A single overhead channel can be selected for Text-based setup and monitoring of all trace Overhead Trace capture. 256 unique values of the selected channel messages (J0, J1, J2, TC-APId (VC-3/4, VC-4-Nc), Sequence messages(J0, are displayed along with the number of frames TC-APId (VC-11/12).
  • Page 19: Virtual Concatenation Delay Generation

    OmniBER OTN Communications Performance Analyzers Virtual Concatenation Delay Generation Alarms SDH transmit Physical: LOS triggers Section O/H: LOF, OOF, MS-AIS, MS-RDI, Up to 256ms can be added to any or all members of the Delay Path O/H: AU-AIS, AU-AIS-C, AU-LOP, AU-LOP-C, virtual concatenated.
  • Page 20: Gcc/Dcc Drop/Insert

    OmniBER OTN Communications Performance Analyzers GCC/DCC drop/insert Payload drop/insert capabilities Supports the drop and insert of DCC channels from SONET/SDH or GCC Supports the external drop/insert of asynchronous DSn/PDH channels from OTN signals mapped DSn/PDH payloads. Drop/insert is to/from performed via the instrument's DSn/PDH electrical SONET test ports.
  • Page 21: Dsn/Pdh Testing

    OmniBER OTN Communications Performance Analyzers DSn/PDH testing Additional features On-line user documentation: Accessed via front Help facilities panel key. DS1 loopcodes and DS3 FEAC messages Context-sensitive help: Provided for each control-field on a dedicated line of the instrument's display. The displayed help information automatically Transmits and monitors in-band and out-of-band DS1 DS1 loopcodes tracks the cursor.
  • Page 22: General Specifications

    Windows® is a U.S. registered trademark of Microsoft Corporation. JavaTM is a U.S. trademark of Sun Microsystems, Inc Agilent Technologies manufactures the OmniBER OTN family under a quality system approved to the international standard ISO 9001 plus TickIT (BSI Registration Certificate...
  • Page 23 This page intentionally left blank.
  • Page 24 Fax: (64-4) 802-6881 routers, next generation SONET/SDH Multi-Service Provisioning Platforms and many other devices. For more information refer to publication no 5988-9860EN. www.agilent.com/comms/omniber www.agilent.com/comms/omniber Copyright © Agilent Technologies, Inc. 2002 Specifications subject to change Printed in USA, January 8, 2004 5988-9564EN...

This manual is also suitable for:

Omniber otn j7230b

Table of Contents