RRP 6-68 Traverse Motor Assembly (PL 20.13)
Fig 6-57 Traverse Motor Assembly
Removal
1.
Remove the Stapler Base Assembly (RRP 6-64).
2.
Remove two screws that secure the Damper (PL 20.13.3) to the large frame of
the stapler, and remove the Damper together with the Gear (PL 20.13.4) and
Motor Assembly-MP8 (PL 20.13.5).
Replacement
1.
Align the Damper, together with the Gear and Motor Assembly-MP8, with the
large frame of the stapler, and secure them with two screws.
2.
Mount the Stapler Base Assembly (RRP 6-64).
Figure 1
Figure 2
Volume 6 / Finisher - RRPs
S4525-490