YASKAWA DX200 Maintenance Manual page 853

Hide thumbs Also See for DX200:
Table of Contents

Advertisement

Alarm Name
Alarm
Sub
Number
Code
5
6
7
8
303
4258
MOTOWELD FEEDER
1
ERROR
Meaning
Cause
Error from welder 5.
Arc welding power source
error
Error from welder 6.
Arc welding power source
error
Error from welder 7.
Arc welding power source
error
Error from welder 8.
Arc welding power source
error
Sub code: Error No. from
Arc welding power source
welder.
error
Error from welder 1.
Arc welding power source
error
other
Remedy
(1) Check the DIP switch setting of PR(CR) -002R1 board.
(2) PR(CR) -002R1 board may be broken. Contact your YASKAWA
representative.
(1) Check the DIP switch setting of PR(CR) -002R1 board.
(2) PR(CR) -002R1 board may be broken. Contact your YASKAWA
representative.
(1) Check the DIP switch setting of PR(CR) -002R1 board.
(2) PR(CR) -002R1 board may be broken. Contact your YASKAWA
representative.
(1) Check the DIP switch setting of PR(CR) -002R1 board.
(2) PR(CR) -002R1 board may be broken. Contact your YASKAWA
representative.
(1) Check the DIP switch setting of PR(CR) -002R1 board.
(2) PR(CR) -002R1 board may be broken. Contact your YASKAWA
representative.
Confirm the following content.
(1)The encoder cable be not damaged?
(2)Isn't there loosening of the screw of the encoder cable connection
terminal block?
When there are a disconnection of the encoder cable or loosening of
the screw, the wire feeding speed quickens abnormally, and it
becomes an abnormal amount of feeding. Replace the encoder cable
or fasten the screw of the terminal block.
(3)Check if the wire load becomes heavy. Make sure that the torch
cable and conduit cable are not bent excessively.
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).