Alarm Name
Alarm
Sub
Number
Code
4546
CANNOT EXECUTE
SYSTEM JOB
4547
PRIMITIVE ERROR
4548
CANNOT OPERATE
SPECIFIED EVENT
4549
NOT EXECUTION OF
INIEVNT
4550
CANNOT EXECUTE
INST(USER JOB)
4551
CANNOT MEASURE
TIP INSTALL COEF
4565
SOFTWARE
1
UNMATCH
Meaning
Cause
Sub Code: System number
Software operation error
occurred
Sub Code: Error code
Software operation error
occurred
Sub Code: System number
Software operation error
occurred
Sub Code: System number
Setting error
other
Sub Code: System number
Setting error
other
Sub Code: Gun number
Setting error
other
The multi-layer welding
Software operation error
function is not used.
occurred
Remedy
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
(1)Check the following settings.
Execute an INIEVNT instruction before executing an event related
instruction.
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
(1)Check the following settings.
This instruction cannot be executed in the system job. Correct the job
so that the instruction is executed in the user job.
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
(1)Check the following settings.
Execute the "SVGUNCL TWC-AE", and then execute the "SVGUNCL
TWC=BE".
If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).